About this trial
In contemporary clinical practice concerning the administration of inhaled nitric oxide (iNO) within neonatal intensive care units (NICUs), a stepwise reduction approach is frequently employed in accordance with established neonatal guidelines. Nonetheless, the comparative advantages of a linear reduction strategy-characterized by a gradual decrease in inhalation concentration-over the traditional stepwise method in terms of efficacy and safety have yet to be conclusively established. Furthermore, existing iNO delivery devices necessitate that healthcare professionals manually adjust parameters at intervals dictated by the patient's condition. This reliance on subjective clinical judgment often results in variability and a lack of standardization in the duration of the weaning process. Additionally, the protracted and intricate nature of the weaning procedure considerably heightens the workload for healthcare staff. Importantly, the development of a scientifically grounded, standardized, and real-time feedback mechanism for weaning may enhance clinical outcomes for patients and mitigate the risks associated with inappropriate weaning practices or inconsistent manual interventions. Consequently, this study seeks to leverage the newly introduced "intelligent closed-loop weaning" feature of the latest generation of iNO devices to facilitate automated linear concentration reduction during the weaning process. This innovation aims to alleviate the burden on healthcare personnel while establishing a more standardized and scientifically robust weaning protocol. However, it is noteworthy that there is currently a lack of clinical evidence, both domestically and internationally, regarding the safety and efficacy of this device's weaning protocol, underscoring the urgent need to validate its safety and effectiveness in real-world clinical settings.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
The administration of inhaled nitric oxide (iNO) has commenced or is anticipated to commence for a duration of 24 hours or more, based on a clinical diagnosis of persistent pulmonary hypertension of the newborn (PPHN);
There is a demonstrable positive response to iNO treatment;
The iNO delivery system employed is appropriate and meets the conditional requirements, featuring an intelligent closed-loop offline functionality;
The guardian or legal representative possesses a comprehensive understanding of the potential benefits and risks associated with participation in this study and has expressed a willingness to consent by signing the informed consent document.
Disqualifiers
Severe hypoplasia of the left heart or duct-dependent congenital heart disease;
Life-threatening congenital anomalies and congestive heart failure;
Congenital methemoglobinemia;
Significant hemorrhagic events, such as intracranial hemorrhage, intraventricular hemorrhage, and pulmonary hemorrhage.
Trial design
Sequential
Treatments tested in this trial
Nitric Oxide Generation and Delivery System
DeviceThe Nitric Oxide Generation and Delivery System is used to deliver nitric oxide for inhalation therapy into the inspiratory limb of the patient breathing circuit in a way that provides a constant concentration of nitric oxide (NO), as set by the user, to the patient throughout the inspired breath. iNO devices with intelligent closed-loop offline function are required to meet the import and discharge standards. The initial concentration of NO withdrawal is 20ppm. In accordance with the withdrawal criteria outlined in the Chinese Guidelines, it is essential to conduct a comprehensive efficacy evaluation prior to initiating withdrawal. Furthermore, the process of inhaled nitric oxide (iNO) evacuation should commence only if specific conditions are satisfied.
Treatment groups
Trial outcomes
Primary outcomes
The occurrence of nitric oxide (NO) rebound hypoxia during the evacuation process
The occurrence of nitric oxide (NO) rebound hypoxia during the evacuation process, operationally defined as the frequency of instances in which peripheral capillary oxygen saturation (SpO2) decreased by more than 5% and the fraction of inspired oxygen (FiO2) increased by 15% in order to maintain partial pressure of arterial oxygen (PaO2) above 60 mmHg (with SpO2 ≥ 90%) during the evacuation of NO
The total duration of inhaled nitric oxide (iNO) evacuation
The entire length of time required to remove or discontinue the use of iNO.
Secondary outcomes
Device Alarm Frequency
The frequency of device alarms recorded during the evacuation process.
NO Concentration Adjustments
The total number of adjustments made to knobs and settings for nitric oxide concentration during evacuation.
Mechanical Ventilation Duration
The duration of mechanical ventilation.
Adverse Events Incidence
The incidence of adverse events associated with nitric oxide treatment.