Closed-loop Medtronic 780G System in Youth With Type 1 Diabetes

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age1-21
SponsorSheba Medical Center

About this trial

The goal of this observational study is to describe data on Israeli children and youth using the 780G system including data regarding glycemic control parameters, various questionnaires, sleep data, bioimpedance measures, and dietary parameters. The main questions it aims to answer are: • whether the 780G system will improve glycemic control • whether the psychosocial aspects will improve. Participants will be followed once connected to 780G, at baseline, one, three, six months, 1 year, and two years after the connection.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

None

Disqualifiers

None

Trial population

The study population will include individuals with type 1 diabetes ages 1-21 years who are managed by the pediatric diabetes teams from the AWeSoMe Study Group (five pediatric diabetes multidisciplinary clinics in Israel; Dana-Dwek Children's Hospital, Edmond and Lily Safra Children's Hospital, Maccabi National Juvenile Diabetes Center, Shamir Medical Center and Wolfson Medical Center) and who chose to purchase 780G out-of-pocket as part of their diabetes care, or are eligible according to the updated Israeli basket to receive it. The decision to use 780G will be made prior to and independent of their entrance to the study, and will be based on preferences of the patients and their parents.

Trial design

Design model

Case-only

Time perspective

Prospective

Treatments tested in this trial

  • Medtronic 780G® hybrid closed loop

    Device

    Medtronic 780G® hybrid closed loop system uses the commercial "auto-mode" with an insulin pump and continuous glucose monitoring.

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Time spent in range (70-180 mg/dL) as assessed from closed-loop Medtronic 780G system

Change in time spent in range (70-180 mg/dL) from baseline to three months of closed-loop Medtronic 780G system

Time frame
0,3 months
2

Time spent in range (70-180 mg/dL) as assessed from closed-loop Medtronic 780G system

Change in time spent in range (70-180 mg/dL) from baseline to six months of closed-loop Medtronic 780G system

Time frame
0,6 months
3

Time spent in range (70-180 mg/dL) as assessed from closed-loop Medtronic 780G system

Change in time spent in range (70-180 mg/dL) from baseline to six months of closed-loop Medtronic 780G system

Time frame
0,12 months
4

Time spent in range (70-180 mg/dL) as assessed from closed-loop Medtronic 780G system

Change in time spent in range (70-180 mg/dL) from baseline to six months of closed-loop Medtronic 780G system

Time frame
0,24 months

Secondary outcomes

1

HbA1c as assessed from point-of-care clinic visit

Change in HbA1c from baseline to three months of closed-loop Medtronic 780G system

Time frame
0, 3 months
2

HbA1c as assessed from point-of-care clinic visit

Change in HbA1c from baseline to six months of closed-loop Medtronic 780G system

Time frame
0, 6 months
3

Time spent below range (≤ 70 mg/dL) as assessed from closed-loop Medtronic 780G system

Change in time spent below range (≤ 70 mg/dL) baseline to three months of closed-loop Medtronic 780G system

Time frame
0, 3 months
4

Time spent below range (≤ 70 mg/dL) as assessed from closed-loop Medtronic 780G system

Change in time spent below range (≤ 70 mg/dL and ≤ 54 mg/dL) baseline to six months of closed-loop Medtronic 780G system

Time frame
0, 6 months

Other outcomes