About this trial
This study evaluates a new closed-loop rehabilitation system for stroke survivors with arm weakness. The system combines a brain-computer interface (BCI, a special cap that reads brain signals), spinal cord stimulation (a temporary implanted electrode that sends gentle electrical pulses to the spine), and a robotic hand exoskeleton. When the participant imagines moving their affected hand, the system detects this intention from brain signals and immediately triggers the spinal stimulation and robotic assistance to help complete the movement. The goal is to test whether this "brain-spine-hand" closed-loop approach is safe and can improve upper limb function after stroke.
About 30 stroke patients with chronic arm weakness will be enrolled. Participants will first undergo brain signal testing to confirm they can produce detectable movement intentions. Eligible participants will then have a temporary spinal cord stimulator electrode placed under the skin near the spine. Over the next 4 weeks, they will receive daily training sessions (about 90 minutes, 5 days per week) using the closed-loop system. After 4 weeks, the electrode will be removed, and participants will continue standard rehabilitation. Hand and arm function will be assessed before, during, and after the intervention.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18-60 years.
Unilateral upper limb motor dysfunction due to primary stroke.
Stable brain lesion and underlying etiology.
Upper limb motor dysfunction for >6 months with no recent improvement despite standardized rehabilitation (plateau phase).
Disqualifiers
Active infection, fever, or unstable vital signs/intracranial condition.
Need for MRI during device implantation period.
Hypotonic or flaccid paralysis of affected limb.
Other causes of motor dysfunction (e.g., ALS, myasthenia gravis, muscular dystrophy, hypokalemic periodic paralysis, spondylitis, arthritis, osteomyelitis).
Trial design
Single group
Treatments tested in this trial
Spinal Cord Stimulation
DeviceTemporary invasive spinal cord stimulation triggered by motor intention to facilitate neural excitability.
Non-invasive Brain-Computer Interface
DeviceNon-invasive EEG-based system for real-time motor intention detection.
Hand Exoskeleton
DeviceRobotic exoskeleton guiding affected hand to complete grasping movements, synchronized with decoded motor intention and SCS stimulation.
Motor Imagery Rehabilitation Training
BehavioralClosed-loop motor imagery training combining BCI, SCS, and exoskeleton feedback.
Treatment groups
Trial outcomes
Primary outcomes
Change From Baseline in Fugl-Meyer Assessment for Upper Extremity (FMA-UE) Score
Change in upper limb motor function measured using the Fugl-Meyer Assessment for Upper Extremity (FMA-UE). The total score ranges from 0 to 66, with higher scores indicating better upper limb motor function. Change is calculated as the score at 1 month after electrode removal minus the baseline score.
Secondary outcomes
Change in Action Research Arm Test Score
Upper limb functional performance will be evaluated using the Action Research Arm Test (ARAT), which assesses grasp, grip, pinch, and gross arm movements. The total score ranges from 0 to 57, with higher scores indicating better upper limb function. Change will be calculated as the score at 1 month after electrode removal minus the score at Week 4 of stimulation.
Change in Brunnstrom Recovery Stage of the Upper Extremity
Motor recovery of the affected upper extremity will be assessed using the Brunnstrom Recovery Stages. Recovery is classified into six stages, ranging from Stage I (flaccidity without voluntary movement) to Stage VI (near-normal voluntary movement and coordination). Higher stages indicate better motor recovery. Change will be calculated as the stage at 1 month after electrode removal minus the stage at Week 4 of stimulation.
Change in Nine-Hole Peg Test Completion Time
Fine motor dexterity of the affected hand will be assessed using the Nine-Hole Peg Test (NHPT). The time required to place and remove nine pegs will be recorded in seconds. Shorter completion times indicate better fine motor performance. Change will be calculated as the completion time at each follow-up assessment minus the completion time at electrode removal.
Change in Grip Strength of the Affected Hand
Grip strength of the affected hand will be measured using a hand dynamometer and recorded in kilograms (kg). Higher values indicate greater grip strength. Change will be calculated as the grip strength at each follow-up assessment minus the grip strength at electrode removal.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Beijing Tiantan Hospital
Lead sponsor
ZhongGuancun YiXin Institute Of Medical Engineering
Collaborator
This trial is not recruiting at the moment. You can still explore other options: