About this trial
A prior research indicated that asynchrony between the patient and ventilator occurred in 33 percent of 19,175 breaths, and was seen in every patient. The most prevalent kind of asynchrony was ineffective triggering (68%), followed by delayed termination (19%), double triggering (4%) and premature termination (3%). Asynchrony between the patient and ventilator increased considerably with decreasing levels of peak inspiratory pressure, positive end-expiratory pressure, and set frequency.Despite this, more asynchrony categories exist, and there is no widely accepted categorization. Major asynchronies, however, include auto trigger, ineffective effort, and double trigger, while minor asynchronies include early/late cycle, trigger delay, and spontaneous breaths during a mandatory breath. This study aims to compare the safety and efficacy of a closed-loop synchronization controller with conventional control of synchronization during invasive mechanical ventilation of spontaneous breathing of pediatric patients in a pediatric intensive care unit (PICU).
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Pediatric patients older than 1 month and younger than18 years of age
Hospitalized at the PICU with the intention of treatment with mechanical ventilation at least for the upcoming 3 hours with spontaneous breathing activity
Written informed consent signed and dated by the patient or one relative in case that the patient is unable to consent, after full explanation of the study by the investigator and prior to study participation
Disqualifiers
Formalized ethical decision to withhold or withdraw life support
Patient included in another interventional research study under consent
Patient already enrolled in the present study in a previous episode of respiratory failure
Pregnant woman
Trial design
Crossover
Treatments tested in this trial
close-loop synchronization controller with SPONT mode
DeviceOne-hour period where the pressure support of spontaneous breath will be automatically titrated based on pressure and flow waveform analysis obtained from the patient.
Conventional synchronization settings with SPONT mode
DeviceOne-hour period where the pressure support of spontaneous breath will be manually set.
Treatment groups
Trial outcomes
Primary outcomes
Asynchrony Index
\[(major asynchronies+minor asynchronies )/(total number of breaths + ineffective efforts)\]x100
Secondary outcomes
Major asynchronies
\[(major asynchronies)/(total number of breaths + ineffective efforts)\]x100
Minor asynchronies
\[(minor asynchronies)/(total number of breaths + ineffective efforts)\]x100
Comfort Behavioral Score
The Comfort Behavioral Scale yields points based on scores obtained from the Comfort B Scale. Scores below 10 indicate that the patient may be over-sedated, while scores between 12 and 17 suggest that the patient is adequately comfortable. Scores above 17 may suggest that the patient is experiencing inadequate sedation
Leak
Percentage of leak around endotrachel tube (%)
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Dr. Behcet Uz Children's Hospital
Lead sponsor
Hamilton Medical AG
Collaborator