About this trial
This study aims to compare three-dimensional (3D) and two-dimensional (2D) visualization in biportal endoscopic spine surgery using a simulated environment. Surgeons will perform standardized tasks on a spine model while using either 3D or 2D endoscopic systems. The goal is to determine whether 3D technology can improve precision, efficiency, and movement control during surgery. The study uses a randomized, blinded, crossover design to ensure objective results and may help guide future training and technology use in spinal endoscopy.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Enrolled in the neurosurgical residency or fellowship program at the Department of Neurosurgery, Cantonal Hospital of St. Gallen, Switzerland
Completion of basic neurosurgical training modules, including introductory endoscopic handling
Age ≥ 18 years
Willingness and ability to provide informed consent
Disqualifiers
Prior substantial experience with three-dimensional (3D) endoscopy (defined as > 5 independent procedures performed with 3D visualization systems)
Ocular or neurological conditions impairing stereopsis, fine motor control, or safe endoscope handling
Inability or unwillingness to complete the simulation protocol
Declined participation
Trial design
Crossover
Treatments tested in this trial
Three-Dimensional Endoscopic Visualization
DeviceUse of a stereoscopic 3D high-definition endoscopic system with dual optical channels, projecting to a stereoscopic monitor viewed with polarized glasses, to perform standardized spinal simulation tasks.
Two-Dimensional Endoscopic Visualization
DeviceUse of the same high-definition endoscopic system with stereoscopic function deactivated, providing conventional monoscopic two-dimensional visualization, to perform standardized spinal simulation tasks.
Treatment groups
Trial outcomes
Primary outcomes
Difference in Task Completion Time (seconds) and Error Rate During Spinal Endoscopic Simulation, Assessed Immediately Post-Task
Task performance was assessed during standardized spinal endoscopic simulation tasks under both three-dimensional (3D) and two-dimensional (2D) visualization. Task completion time was measured in seconds with a digital stopwatch from the start to the successful completion of each task. Task accuracy was assessed as the number of predefined errors, including deviations from the optimal trajectory or inadvertent contact with marked "no-go" zones on the simulation model. Both measures were collected immediately during each simulation session. Lower times and fewer errors indicate better performance.
Difference in Task Completion Time (seconds) and Error Rate During Spinal Endoscopic Simulation, Assessed Immediately Post-Task
Task performance was assessed during standardized spinal endoscopic simulation tasks under both three-dimensional (3D) and two-dimensional (2D) visualization. Task completion time was measured in seconds with a digital stopwatch from the start to the successful completion of each task. Task accuracy was assessed as the number of predefined errors, including deviations from the optimal trajectory or inadvertent contact with marked "no-go" zones on the simulation model. Both measures were collected immediately during each simulation session. Lower times and fewer errors indicate better performanc