About this trial
The purpose of this randomized controlled trial is to compare the efficacy and safety of two epidural analgesia maintenance methods for labor pain relief: Programmed Intermittent Epidural Bolus (PIEB) and Continuous Epidural Infusion (CEI), both combined with Patient-Controlled Epidural Analgesia (PCEA). The study aims to evaluate which technique provides superior analgesia while minimizing anesthetic consumption and preserving maternal motor function. A total of 60 parturients at Family Hospital, Da Nang, will be randomly assigned to either the PIEB or CEI group. Outcomes including pain intensity (VAS scores), total drug consumption, maternal satisfaction, and neonatal Apgar scores will be assessed.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Parturients indicated for labor analgesia for vaginal delivery via epidural anesthesia.
Age from 18 to 40 years.
Physical status: ASA II.
Singleton pregnancy, full-term, vertex presentation in labor.
Disqualifiers
Contraindications to epidural analgesia.
History of allergy to local anesthetics (Ropivacaine) or opioids (Fentanyl).
High-risk pregnancies: Preeclampsia, placenta previa, placental abruption.
Fetal distress or fetal abnormalities.
Trial design
Parallel
Treatments tested in this trial
PIEB + PCEA
Procedure/SurgeryInitial dose: 10 mL (0.1% Ropivacaine + 2 mcg/mL Fentanyl). Maintenance: 8 mL bolus every 60 mins. PCEA: 5 mL bolus, 10-min lockout.
CEI + PCEA
Procedure/SurgeryInitial dose: 10 mL (0.1% Ropivacaine + 2 mcg/mL Fentanyl). Maintenance: Continuous infusion at 8 mL/hour. PCEA: 5 mL bolus, 10-min lockout.
Treatment groups
Trial outcomes
Primary outcomes
Labor Pain Intensity
Pain intensity is assessed using the Visual Analog Scale (VAS), a self-reported scale where 0 represents "no pain" and 10 represents "the worst pain imaginable". Lower scores indicate better analgesic efficacy. Score on a scale from 0 to 10.
Secondary outcomes
Total Ropivacaine Consumption
The total dose of Ropivacaine (in milligrams) administered to each participant throughout the entire labor and delivery process. This sum includes the 10 mg initial manual bolus , the programmed intermittent boluses (8 mg/hour) or continuous infusion (8 mg/hour) , and any 5 mg patient-controlled epidural analgesia (PCEA) or manual rescue doses administered.
Incidence of Maternal Motor Block
The presence and severity of motor blockade are evaluated using the Modified Bromage Scale (0 = No motor block; 1 = Inability to raise extended legs; 2 = Inability to flex knees; 3 = Inability to flex ankles). Higher scores mean a worse outcome (greater motor impairment).
Maternal Satisfaction Score
Overall satisfaction is assessed using a 5-point Likert scale. The scale ranges from 1 to 5, where 1 indicates "Not Satisfied" and 5 indicates "Very Satisfied". Higher scores mean a better outcome (greater satisfaction).
Neonatal Apgar Scores
Newborn health is assessed using the Apgar Scale. The total score ranges from 0 to 10, calculated based on five criteria (each scored 0-2). Higher scores mean a better outcome (better neonatal condition).