About this trial
This study looks at three ways to help manage pain without medication: virtual reality (using a VR headset to create an immersive distraction), hypnosis (using guided relaxation and suggestion), and a combination of both. Researchers want to know which approach - or combination - works best at reducing pain and discomfort.
Forty healthy adults will take part in a single research visit lasting about 140 minutes. During the visit, participants will experience mild, controlled pain from a small electrical stimulation on the ankle, adjusted to a level they can tolerate. They will try all three approaches (virtual reality, hypnosis, and the combination) during the same visit, in a random order. Throughout the visit, researchers will record how much pain and discomfort participants feel, along with body signals such as heart rate, breathing, skin response, and brain activity (using a comfortable EEG cap with no needles).
The goal is to better understand how these non-drug approaches work and whether combining them provides more relief than using either one alone. This research may help improve pain management for people undergoing medical procedures in the future.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Adults aged 18 to 35 years
Fluency in French (validated French-language versions of all instruments and the hypnotic script)
Capacity to provide free and informed consent
Good general health, without uncontrolled acute or chronic pathology
Disqualifiers
History of major neurological disorders (epilepsy, severe head trauma, multiple sclerosis) or major psychiatric disorders (psychosis, dissociative disorders, active post-traumatic stress disorder)
Current use of medication likely to affect pain perception or central nervous system activity (opioids, benzodiazepines, anticonvulsants, tricyclic antidepressants, gabapentinoids)
Alcohol or psychoactive substance use within 24 hours prior to the session
Use of analgesics (e.g., ibuprofen, acetaminophen, aspirin) within 24 hours prior to the session
Trial design
Crossover
Treatments tested in this trial
Virtual reality
BehavioralImmersive virtual reality experience using a VR headset, delivered via commercially available VR content.
Hypnosis
BehavioralStandardized hypnotic induction protocol with analgesic suggestions, delivered by trained research personnel using a verbatim script.
Treatment groups
Trial outcomes
Primary outcomes
Pain intensity
Pain intensity in response to the individually calibrated transcutaneous electrical stimulation of the sural nerve, rated on an 11-point Numeric Rating Scale (NRS) for pain intensity (minimum 0 = no pain, maximum 10 = worst pain imaginable; higher scores indicate a worse outcome). One rating is collected after each experimental condition (virtual reality, hypnosis, combined virtual reality and hypnosis).
Pain unpleasantness
Pain unpleasantness (affective dimension of pain) in response to the individually calibrated transcutaneous electrical stimulation of the sural nerve, rated on an 11-point Numeric Rating Scale (NRS) for pain unpleasantness (minimum 0 = not unpleasant, maximum 10 = most unpleasant imaginable; higher scores indicate a worse outcome). One rating is collected after each experimental condition (virtual reality, hypnosis, combined virtual reality and hypnosis).
Secondary outcomes
Anxiety
Self-reported anxiety rated on an 11-point Numeric Rating Scale (NRS) for anxiety (minimum 0 = no anxiety, maximum 10 = extreme anxiety; higher scores indicate a worse outcome), collected after each experimental condition (virtual reality, hypnosis, combined virtual reality and hypnosis).
Emotional distress
Self-reported emotional distress rated on an 11-point Numeric Rating Scale (NRS) for emotional distress (minimum 0 = no distress, maximum 10 = extreme distress; higher scores indicate a worse outcome), collected after each experimental condition (virtual reality, hypnosis, combined virtual reality and hypnosis).
Negative affect
Self-reported negative affect rated on an 11-point Numeric Rating Scale (NRS) for negative affect (minimum 0 = none, maximum 10 = extreme; higher scores indicate a worse outcome), collected after each experimental condition (virtual reality, hypnosis, combined virtual reality and hypnosis).
Perceived control over pain
Self-reported sense of control over pain rated on an 11-point Numeric Rating Scale (NRS) for perceived control (minimum 0 = no control, maximum 10 = complete control; higher scores indicate a better outcome), collected after each experimental condition (virtual reality, hypnosis, combined virtual reality and hypnosis).
Other outcomes
EEG alpha-band power (8-12 Hz)
Absolute spectral power in the alpha band (8-12 Hz), recorded with a 24-channel dry-electrode electroencephalography (EEG) system (500 Hz sampling rate) during the painful stimulation phase of each experimental condition (virtual reality, hypnosis, combined), averaged across channels. Reported in microvolts squared per hertz (µV²/Hz).
EEG theta-band power (4-7 Hz)
Absolute spectral power in the theta band (4-7 Hz), recorded with a 24-channel dry-electrode electroencephalography (EEG) system (500 Hz sampling rate) during the painful stimulation phase of each experimental condition (virtual reality, hypnosis, combined), averaged across channels. Reported in microvolts squared per hertz (µV²/Hz).
EEG beta-band power (13-30 Hz)
Absolute spectral power in the beta band (13-30 Hz), recorded with a 24-channel dry-electrode electroencephalography (EEG) system (500 Hz sampling rate) during the painful stimulation phase of each experimental condition (virtual reality, hypnosis, combined), averaged across channels. Reported in microvolts squared per hertz (µV²/Hz).
EEG gamma-band power (30-80 Hz)
Absolute spectral power in the gamma band (30-80 Hz), recorded with a 24-channel dry-electrode electroencephalography (EEG) system (500 Hz sampling rate) during the painful stimulation phase of each experimental condition (virtual reality, hypnosis, combined), averaged across channels. Reported in microvolts squared per hertz (µV²/Hz).