About this trial
This randomized split-face study aims to compare the effects of 26G and 30G needles used for masseter trigger point injections with lidocaine in patients with myofascial pain syndrome. Both needle sizes are routinely used in clinical practice. Pain reduction from baseline to day 14 will be compared between the two sides of the face. Secondary outcomes include pain reduction at day 7, procedural pain, injection-site tenderness at 48 hours, bruising, and patient preference. The split-face design allows both needle sizes to be evaluated in the same patient, minimizing individual differences.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
None
Disqualifiers
Concomitant temporomandibular joint arthralgia.
Trial design
Single group
Treatments tested in this trial
26G Needle
DeviceA 26-gauge (0.45 × 13 mm) needle was used for masseter trigger point injection. A total of 0.3 mL of 2% lidocaine without vasoconstrictor was administered using a standardized injection technique.
30 Gauge Needle
DeviceA 30-gauge (0.45 × 13 mm) needle was used for masseter trigger point injection. A total of 0.3 mL of 2% lidocaine without vasoconstrictor was administered using a standardized injection technique.
Treatment groups
Trial outcomes
Primary outcomes
Between-Needle Difference in Palpation-Evoked Masseter Pain Reduction From Baseline to Day 14
Palpation-evoked masseter pain was assessed separately on each side using an 11-point Numerical Rating Scale (NRS), ranging from 0 (no pain) to 10 (worst possible pain). At baseline and day 14, pain was recorded at the most painful trigger point identified during each assessment. Pain reduction was calculated as baseline NRS minus day 14 NRS for each side. The primary outcome was the within-participant difference in pain reduction between the 30G and 26G needle interventions (30G minus 26G). Positive values indicated greater pain reduction with 30G.
Secondary outcomes
Between-Needle Difference in Palpation-Evoked Masseter Pain Reduction at Day 7
Palpation-evoked masseter pain was assessed separately on each side using an 11-point Numerical Rating Scale (NRS), ranging from 0 (no pain) to 10 (worst possible pain). Pain reduction was calculated as baseline NRS minus day 7 NRS for each side. The within-participant difference in pain reduction between the 30G and 26G needle interventions was calculated as 30G minus 26G. Positive values indicated greater pain reduction with 30G.
Other outcomes
Overall Procedural Pain During Masseter Trigger Point Injection
Overall procedural pain was assessed separately for the 26G and 30G needle interventions using an 11-point Numerical Rating Scale (NRS), ranging from 0 (no pain) to 10 (worst possible pain). Participants rated the entire injection procedure, including skin penetration, intramuscular needle manipulation, and lidocaine administration. Pain was recorded within 60 seconds after each injection. Within-participant pain scores were compared between needle gauges.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: