Comparison of Cytokines Profile in Aqueous Humor and Tear Before and After UCP Treatment

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
AgeNot listed
SponsorZhongshan Ophthalmic Center, Sun Yat-sen University

About this trial

Glaucoma is the leading cause of irreversible vision loss in people aged 50 years and older worldwide, second only to cataracts. Ultrasound Cyclo Plasty was first proposed as a new minimally invasive technique in the 1980 s. In recent years, many clinical studies at home and abroad have confirmed the effectiveness, safety and repeatability of UCP. The ciliary body is the target organ of UCP, and the range and accuracy of intraoperative destruction of the ciliary body are the key factors affecting the success or failure of the operation. The production of aqueous humor is closely related to the ciliary body. The dynamic balance of its production and discharge can affect IOP, and its content can directly reflect the intraocular environment. Besides,tears are easy to collect and can be used for follow-up. Previous studies have shown that various proteins in aqueous humor or tear can provide a basis for the pathophysiological changes of glaucoma, and can also be a potential biomarker for predicting the success of anti-glaucoma surgery.

At present, UCP related research focuses on its effectiveness and safety, mainly reflected in three aspects : postoperative intraocular pressure, number of anti-glaucoma drugs and complications, and lack of relevant indicators that directly reflect postoperative intraocular environment changes. The purpose of this study was to reveal the changes of cytokines in aqueous humor after UCP in patients with primary glaucoma, to analyze the possible causes of these factors, and to speculate the effect of their interaction on the surgical effect, in order to increase the predictability of UCP procedure.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

The patient was definitely diagnosed as glaucoma, No age or gender limitation, IOP(intraocular pressure) ≥ 21mmHg under the maximum tolerated dose of antiglaucoma medication, or IOP < 21mmHg and glaucomatous optic nerve damage progressed.

Disqualifiers

Other eye diseases that could affect IOP; preoperative use of systemic steroid drugs; history of other anti-glaucoma surgery within 3 months; ocular infection 2 weeks prior to UCP

Trial population

Inpatient sample

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Ultrasound CycloPlasty

    Procedure/Surgery

    All procedures were performed using the EyeOP1 device . The coupling cone was placed and adjusted on the centre of the patient's eye by visualising an equal white scleral ring surrounding the cornea. The coupling cone was kept in place via vacuum suction activated using a foot pedal and was then filled with a balanced salt solution to allow ultrasound transmission. The transducers were automatically activated at a frequency of 21 MHz and an acoustic power of 2.45 W, with an 8-s duration for each sector and a 20-s pause between each treatment to allow complete evacuation of heat.

Treatment groups

200 Participants
are divided into 2 treatment groups
Group A: Matched eyes0 interventions
Group B: Treated eyes with UCP1 intervention

Trial outcomes

Primary outcomes

1

Cytokine profiles(pg/ml)

Cytokine antibody array was used to detect cytokines in AH samples from UCP treatment group and control group. The analysis method is based on the principle of double antibody sandwich immunoassay, and 60 ul of samples are applied on each block. Antibodies against the selected cytokines were immobilized at specific locations on the chip surface. The cytokines in the sample were captured by the corresponding antibody, and a mixture of biotinylated antibodies was added to detect the binding cytokines. Finally, the signal was visualized using a fluorescent dye ( cy3 equivalent ) that binds to streptavidin. The InnoScan 300 Microarray Scanner ( Innopsys, Parc d 'Activités Activestre, Carbonne, France ) was used for fluorescent dye detection.

Time frame
through study completion, an average of 2 year
2

Intraocular pressure(mmHg)

Using non-contact tonometer (NCT) to measure intraocular pressure

Time frame
through study completion, an average of 2 year
3

Anterior segment parameters(mm)

Measured by ultrasound biomicroscopy, parameters included WTW, ciliary body length, ciliary process length and density.

Time frame
through study completion, an average of 2 year

Secondary outcomes

1

LogMAR visual acuity

Using Snellen visual acuity chart to measure naked eye vision and best corrected vision

Time frame
through study completion, an average of 2 year
2

Complications(n,%)

Including conjunctival congestion, corneal edema, corneal epithelial defect, anterior chamber inflammation, pupil deformation,cataract development/progression, etc.

Time frame
through study completion, an average of 2 year

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.