About this trial
The use of neuromuscular blocking (NMB) agents in modern anesthesia is essential for optimizing surgical exposure and ensuring patient safety. Inadequate neuromuscular recovery at the end of surgery, known as residual curarization, poses significant risks for critical postoperative respiratory complications, aspiration pneumonia, and prolonged recovery times. Therefore, objective neuromuscular monitoring is strongly recommended by international guidelines, including the American Society of Anesthesiologists (ASA) and the European Society of Anaesthesiology and Intensive Care (ESAIC).
In gynecologic oncology surgery, laparoscopic and robotic approaches often require deep neuromuscular blockade (Post-Tetany Count 1-2) to improve abdominal exposure and allow surgeons to work at lower intraperitoneal pressures. However, the extreme Trendelenburg position and the "tucked-in" positioning of the arms under surgical drapes limit the feasibility of traditional acceleromyography (AMG) monitoring methods. Since AMG devices require free movement of the thumb (m. adductor pollicis), they can yield false-positive or unreliable results when the arms are inaccessible, forcing clinicians to rely on subjective monitoring.
The NMTCuff technology, used by the Vision Duo monitor, measures the neuromuscular response via the contraction pressure of the upper arm muscles (m. triceps/biceps brachii) rather than the wrist. Literature indicates that the response of upper arm muscles correlates better with the diaphragm and laryngeal muscles regarding NMB sensitivity compared to the wrist. This feature suggests that the Vision Duo might detect the recovery of respiratory functions earlier and more reliably.
This study aims to evaluate the correlation and time differences in Train-of-Four (TOF) ratios between the NMTCuff and standard AMG methods during gynecologic oncology surgery. Additionally, it will assess the ease of setup and signal continuity of both devices when the patient's arms remain covered under surgical drapes.
This study is purely prospective and observational in terms of clinical management. The neuromuscular monitoring methods used will not interfere with routine anesthesia care, drug dosing, muscle relaxant reversal strategies, or extubation decisions. The clinician performing the anesthesia management will follow the institutional routine protocol, and data from both devices will only be recorded simultaneously and matched for statistical comparison.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Female patients scheduled for elective laparoscopic gynecologic oncology surgery
Aged between 18 and 75 years
American Society of Anesthesiologists (ASA) physical status I-III
Patients who provide written and verbal informed consent
Disqualifiers
Known history of neuromuscular disease
Severe hepatic or renal insufficiency
Body Mass Index (BMI) greater than 35 kg/m2
Patient refusal to participate
Trial population
Female patients aged 18-75 years with an ASA status of I-III who are scheduled to undergo elective laparoscopic gynecologic oncology surgery at Dr. Abdurrahman Yurtarslan Oncology Training and Research Hospital.
Trial design
Cohort
Prospective
Treatments tested in this trial
Dual Neuromuscular Transmission Monitoring
Other interventionSimultaneous recording and matching of data from two different neuromuscular monitoring devices: NMTCuff (Vision Duo) utilizing pressure-sensitive sensors on the non-dominant upper arm, and standard Acceleromyography (AMG) on the contralateral wrist. This monitoring is part of the standard routine anesthesia care and does not interfere with clinical decisions.
Treatment groups
Trial outcomes
Primary outcomes
Time to Neuromuscular Recovery (TOF Ratio >= 0.90)
The time interval (measured in minutes) from the exact moment of the neuromuscular blockade reversal agent (Sugammadex 2 mg/kg) administration until the Train-of-Four (TOF) ratio reaches 90%. This recovery time will be tracked and recorded simultaneously for both the NMTCuff (Vision Duo) and the standard acceleromyography (AMG) devices using a digital stopwatch to evaluate the limits and correlation between the two monitoring methods.
Secondary outcomes
Technical Feasibility and Signal Continuity Under Surgical Drapes
Evaluation of device installation ease, maintenance of stable sensor connections, and the frequency/duration of any signal loss during the operation. This measure assesses the clinical utility of both devices specifically when the patient's arms are tucked-in along their sides and completely covered under surgical drapes in the extreme Trendelenburg position.