Comparison of Physiological Effects of Two High-Flow Tracheal Oxygen Versus T-Piece During Spontaneous Breathing Trials

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorJian-Xin Zhou

About this trial

Spontaneous breathing trials (SBT) are essential for assessing extubation tolerance, yet optimal approaches are debated. High-flow nasal oxygen offers benefits like precise oxygen delivery, flow-related positive end-expiratory pressure generation and improved lung function. While high-flow tracheal oxygen can also be used as an SBT method, it has reduced physiological effects due to bypassing the upper airway with a more open circuit. To enhance this limitation, investigators developed a modified high-flow tracheal oxygen tube with a smaller expiratory end diameter to increase expiratory resistance and airway pressure. This is a prospective randomized crossover study that aims to compare the physiological effects of standard and modified high-flow tracheal oxygen versus T-piece during SBT.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Mechanical ventilation for more than 24 hours

Considered by the physicians for the readiness to wean and ready for spontaneous breathing trials

Disqualifiers

Age younger than 18 years old

Pregnancy

Hemodynamic instability (mean arterial pressure <60 mmHg, heart rate >140 or <60 bpm)

Respiratory and oxygenation instability (respiratory rate > 35bpm or oxygen saturation measured by pulse oximetry <90%)

Trial design

Design model

Crossover

Treatments tested in this trial

  • Modified high flow tracheal oxygen-40L/min

    Procedure/Surgery

    Modified high-flow tracheal oxygen with a flow rate of 40L/min will be performed.

  • Standard high flow tracheal oxygen-40L/min

    Procedure/Surgery

    Standard high-flow tracheal oxygen with a flow rate of 40 L/min will be performed.

  • T-piece

    Procedure/Surgery

    T-piece will be performed.

  • Modified high-flow tracheal oxygen-60L/min

    Procedure/Surgery

    Modified high-flow tracheal oxygen with a flow rate of 60L/min will be performed.

  • Standard high-flow tracheal oxygen-60 L/min

    Procedure/Surgery

    Standard high-flow tracheal oxygen with a flow rate of 60 L/min will be performed.

Treatment groups

20 Participants
are divided into 5 treatment groups
Group A: Modified high flow tracheal oxygen-40L/minExperimental treatment 1 intervention
Group B: Standard high flow tracheal oxygen-40L/minExperimental treatment 1 intervention
Group C: T-pieceExperimental treatment 1 intervention
Group D: Modified high-flow tracheal oxygen-60L/minExperimental treatment 1 intervention
Group E: Standard high-flow tracheal oxygen-60L/minExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Mean expiratory airway pressure

Mean expiratory airway pressure will be measured during standard and modified high-flow tracheal oxygen versus T-piece.

Time frame
From enrollment to the end of treatment at 4 hours
2

Positive end-expiratory pressure

Positive end-expiratory pressure will be measured during standard and modified high-flow tracheal oxygen versus T-piece.

Time frame
From enrollment to the end of treatment at 4 hours
3

Change of end-expiatory lung volume

Change of end-expiatory lung volume will be measured during standard and modified high-flow tracheal oxygen versus T-piece.

Time frame
From enrollment to the end of treatment at 4 hours

Secondary outcomes

1

Respiratory rate

Respiratory rate will be measured during standard and modified high-flow tracheal oxygen versus T-piece.

Time frame
From enrollment to the end of treatment at 4 hours
2

Tidal volume

Tidal volume will be measured during standard and modified high-flow tracheal oxygen versus T-piece.

Time frame
From enrollment to the end of treatment at 4 hours
3

End-tidal carbon dioxide

End-tidal carbon dioxide will be measured during standard and modified high-flow tracheal oxygen versus T-piece.

Time frame
From enrollment to the end of treatment at 4 hours
4

Pulse oxygen saturation

Pulse oxygen saturation will be measured during standard and modified high-flow tracheal oxygen versus T-piece.

Time frame
From enrollment to the end of treatment at 4 hours

Other outcomes