Complex Aortic Aneurysm Repair Using Physician Modified Endografts and Custom Made Devices

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorAndres Schanzer

About this trial

The purpose of this study is to evaluate the safety and efficacy of custom made devices, Zenith t-Branch devices and physician modification of FDA approved off-the-shelf endovascular grafts in the treatment of patients with complex abdominal aneurysms, aortoiliac aneurysms, thoracoabdominal aneurysms and aortic arch aneurysms who (1) have anatomy not suitable for endovascular repair using grafts currently marketed in the United States,(2) are deemed unsafe to wait the required time necessary for commercial endograft manufacturing, and (3) are at high risk for open surgical repair. Amendment to the study has created a cohort open to people with connective tissue diseases such as Marfan, Ehlers-Danlos or Loey-Dietz syndromes to enroll in the trial. An additional amendment to the study allows the use of a custom made device to treat an aneurysm in the aortic arch.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Aortic or aortoiliac aneurysm with diameter ≥5.5 cm

Aortic or aortoiliac aneurysm with a history of growth ≥1.0 cm per year, or clinical indication for aneurysm repair based on symptoms

Cannot be treated with a currently available non-modified approved device

Symptomatic on presentation and unsafe to wait for the time necessary to obtain a currently available non-modified approved device

Disqualifiers

Exclusion Criteria Medical Exclusion Criteria

Cultural objection to receipt of blood or blood products

Allergy or sensitivity to stainless steel, polyester, polypropylene, solder (tin, silver), gold, or nitinol

Anaphylactic reaction to contrast that cannot be adequately pre-medicated

Trial design

Design model

Single group

Treatments tested in this trial

  • Custom Made Fenestrated or Branched Stent Graft

    Device

    The surgeon will place a custom made graft, t-Branch device or modify commercially available stent grafts to match the anatomy of the patient being treated. Small fenestrations (holes) will be made in the stent graft so that additional stents can be inserted through the fenestration and into the blood vessels that lead to the kidneys, intestines or liver. These stents allow blood to flow freely to these organs. If the aneurysm is in the aortic arch stents may be placed in the carotid and subclavian arteries. This surgery is done through small incisions in the groin and sometimes in the upper arm.

Treatment groups

600 Participants
are divided into 1 treatment group
Group A: Endovascular repairExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

The effectiveness of physician modified endovascular grafts will be determined by evaluating the proportion of patients that achieve Treatment Success

Treatment success is a combination of technical success, and freedom at 12 months from the following: Type 1 and 3 Endoleaks, Stent migration of more than 10 mm, aortic aneurysm enlargement sac enlargement of more than 5 mm, aneurysm rupture and conversion to open repair.

Time frame
12 months post procedure

Secondary outcomes

1

Incidence of Major Adverse Events

Major adverse events include death, myocardial infarction, stroke, respiratory failure, paralysis, bowel ischemia, and procedural blood loss of greater than 1 liter.

Time frame
Within 30 days of the initial procedure

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Andres Schanzer

Lead sponsor

University of Massachusetts, Worcester