Computational μFR-Guided Versus Angiographic Guidance in Drug-Coated Balloon Angioplasty

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorCentro Cardiologico Monzino

About this trial

The MAGIC trial is an investigator-initiated, multicenter, randomized (1:1) interventional study designed to evaluate whether drug-coated balloon (DCB) angioplasty guided by computational μFR assessment is superior to conventional angiographic-guided DCB angioplasty in terms of acute physiological outcomes.

The study will enroll approximately 250 patients with de novo lesions in native coronary arteries with a reference vessel diameter (RVD) of 2.0-4.0 mm. Participants will be randomized to one of two treatment strategies.

In the angiography-guided control group, DCB angioplasty will be performed according to conventional angiographic criteria for an optimal procedural result, including TIMI grade 3 flow, residual stenosis of less than 30%, and absence of coronary artery dissections of type C or greater.

In the μFR-guided group, computational μFR will be assessed at baseline, after lesion predilation, and after DCB treatment. Virtual percutaneous coronary intervention (PCI) will be recommended to guide and optimize the angioplasty strategy, with the aim of achieving a final μFR value ≥0.86. If the physiological result remains suboptimal (μFR \<0.86) despite further lesion preparation, a hybrid strategy involving implantation of a drug-eluting stent (DES) will be permitted.

The primary endpoint is the proportion of target vessels with a post-procedure μFR value ≥0.86, as assessed by an independent, blinded core laboratory through analysis of final coronary angiograms.

Clinical follow-up will be conducted exclusively by telephone over a total period of 24 months.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age ≥18 years

Patients with a clinical indication to PCI, either for stable coronary artery disease or acute coronary syndromes

Presence of a de novo lesion in a native coronary artery with a reference vessel diameter >2.0 mm and ≤4.0 mm by visual estimation

Lesion length up to 60 mm

Disqualifiers

Recent ST-elevation myocardial infarction (within 48 hours)

Presence of visible thrombus at the target lesion site

Participation in another investigational clinical trial

Women who are pregnant or breastfeeding

Trial design

Design model

Parallel

Treatments tested in this trial

  • μFR-Based Group (Intervention)

    Procedure/Surgery

    Drug-coated balloon (DCB) angioplasty guided by computational μFR assessment. μFR is measured at baseline, after lesion predilation, and after DCB treatment. Virtual PCI based on μFR is recommended to guide lesion preparation and optimize the angioplasty strategy, targeting a final μFR value ≥0.86. If μFR remains \<0.86 despite further lesion preparation, a hybrid strategy involving drug-eluting stent (DES) implantation is permitted.

Treatment groups

250 Participants
are divided into 2 treatment groups
Group A: Angio-Based Group (Control)No intervention 0 interventions
Group B: μFR-Based Group (Intervention)Experimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Proportion of Target Vessels With Post-Procedure μFR ≥0.86

The primary efficacy endpoint is the proportion of target vessels achieving a post-procedure μFR value ≥0.86, as assessed by an independent, blinded core laboratory based on analysis of the final coronary angiograms.

Time frame
During procedure
2

Incidence of Major Clinical Safety Events at 30 Days

Incidence of the composite safety endpoint including BARC type 3 or 5 bleeding, definite lesion thrombosis or target-segment occlusion, any stroke, any myocardial infarction, and cardiovascular death. The endpoint will be assessed at 30 days after the index procedure.

Time frame
30 days after the index procedure

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Centro Cardiologico Monzino

Lead sponsor

Azienda Ospedaliera Universitaria Integrata Verona

Collaborator