About this trial

This study compares two ways of pacing the heart in adults with atrioventricular block, a condition in which electrical signals do not pass normally from the upper to the lower heart chambers. Participants must need a permanent pacemaker and have a left ventricular ejection fraction of at least 50% before implantation. Ejection fraction measures how much blood the main pumping chamber ejects with each beat.

The study will include 150 participants at Sheba Medical Center. By chance, 50 participants will receive conduction system pacing, which aims to stimulate the heart through its natural electrical conduction system, and 100 will receive conventional right ventricular pacing. Participants and treating clinicians will know which treatment is used.

The main question is whether the two pacing strategies differ in heart pumping function 24 months after implantation, taking the starting measurement into account. Researchers will also compare quality of life, heart-related emergency visits and hospitalizations, complications, pacemaker and lead function, repeat procedures, and use of healthcare resources.

Heart pumping function will be measured before implantation and at 12 and 24 months. Participants will complete the AQUAREL quality-of-life questionnaire before implantation and at 12, 24, 36, 48, and 60 months. Device follow-up will include routine clinical care and remote monitoring.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18 years or older.

Clinical indication for permanent pacemaker implantation due to atrioventricular block.

Pre-implantation echocardiographic left ventricular ejection fraction of at least 50%.

Ability to understand the study and sign informed consent.

Disqualifiers

Unable to provide informed consent.

Estimated life expectancy of less than 12 months.

Severe medical condition likely to prevent completion of follow-up.

Existing indication for cardiac resynchronization therapy at recruitment.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Conduction System Pacing

    Device

    Permanent pacing using a Medtronic SelectSecure MRI SureScan Model 3830 lead targeting His-bundle or left bundle branch area pacing. Final lead placement, fixation, and programming follow electrophysiological measurements and clinical judgment. Where feasible, the same pacemaker generator platform is used in both study arms.

  • Conventional Right Ventricular Pacing

    Device

    Permanent pacemaker implantation with a conventional right ventricular pacing lead placed at a standard right ventricular site according to usual clinical practice at Sheba Medical Center. Device programming and accompanying medical treatment are determined by clinical need.

Treatment groups

150 Participants
are divided into 2 treatment groups
Group A: Conduction System PacingExperimental treatment 1 intervention
Group B: Conventional Right Ventricular PacingActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

Left Ventricular Ejection Fraction at 24 Months

Left ventricular ejection fraction (LVEF), expressed as a percentage and measured by echocardiography at 24 months after implantation. The primary comparison is the between-arm difference adjusted for baseline LVEF and stratification factors as appropriate. The primary analysis follows the intention-to-treat principle.

Time frame
24 months after pacemaker implantation.

Secondary outcomes

1

Change From Baseline in AQUAREL Chest Discomfort Domain Score

Change from baseline in the AQUAREL chest discomfort domain, scored separately using the original algorithm. Domain scores range from 0 to 100; higher scores indicate better quality of life and positive changes indicate improvement. The secondary between-arm comparison at 24 months is adjusted for baseline domain score, with multiplicity addressed across the three domains. The 12-month analysis is exploratory; longer-term scores are also collected.

Time frame
Before pacemaker implantation (baseline) and at 12, 24, 36, 48, and 60 months after implantation.
2

Change From Baseline in AQUAREL Arrhythmia Domain Score

Change from baseline in the AQUAREL arrhythmia domain, scored separately using the original algorithm. Domain scores range from 0 to 100; higher scores indicate better quality of life and positive changes indicate improvement. The secondary between-arm comparison at 24 months is adjusted for baseline domain score, with multiplicity addressed across the three domains. The 12-month analysis is exploratory; longer-term scores are also collected.

Time frame
Before pacemaker implantation (baseline) and at 12, 24, 36, 48, and 60 months after implantation.
3

Change From Baseline in AQUAREL Exertional Dyspnea Domain Score

Change from baseline in the AQUAREL exertional dyspnea domain, scored separately using the original algorithm. Domain scores range from 0 to 100; higher scores indicate better quality of life and positive changes indicate improvement. The secondary between-arm comparison at 24 months is adjusted for baseline domain score, with multiplicity addressed across the three domains. The 12-month analysis is exploratory; longer-term scores are also collected.

Time frame
Before pacemaker implantation (baseline) and at 12, 24, 36, 48, and 60 months after implantation.
4

Ventricular Pacing Burden

Percentage of ventricular beats paced, obtained from device interrogation. Actual pacing burden is an explanatory secondary variable and is not a randomization criterion.

Time frame
Day 1 At pacemaker implantation and at 6, 12, and 24 months after implantation.

Other outcomes

1

Left Ventricular Ejection Fraction at 12 Months

Left ventricular ejection fraction (LVEF), expressed as a percentage and measured by echocardiography at 12 months after implantation. The 12-month comparison is exploratory; the prespecified primary comparison is at 24 months.

Time frame
12 months after implantation

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: