About this trial
This study aims to evaluate the performance of automated subjective refraction performed by operators with different professional backgrounds. By comparing their results with those obtained by a senior optometrist using the same automated refraction program, the study will assess agreement in refractive prescriptions and examine examination efficiency, participant experience, and safety, thereby providing evidence for the further application of automated subjective refraction technology.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Age 7 years or older, of either sex. ② Astigmatism magnitude of 1.50 D or less. ③ Voluntary participation in the study with written informed consent.
Disqualifiers
Concomitant ocular diseases causing opacity of the ocular media, such as cataract, glaucoma, or fundus disease.
History of ocular trauma or intraocular surgery.
Manifest strabismus or significant binocular vision dysfunction. ④ Inability to follow and respond to system instructions. ⑤ Only one eye meeting the eligibility criteria.
Considered unsuitable for participation by the investigator.
Trial design
Crossover
Treatments tested in this trial
Nurse-Operated Automated Subjective Refraction
Diagnostic testA trained nurse operates the automated refraction program to complete the full subjective refraction procedure and obtain spherical power, cylindrical power, and cylinder axis.
Village Doctor-Operated Automated Subjective Refraction
Diagnostic testA trained village doctor operates the automated refraction program to complete the full subjective refraction procedure and obtain spherical power, cylindrical power, and cylinder axis.
Lay Personnel-Operated Automated Subjective Refraction
Diagnostic testTrained lay personnel who have passed competency assessment operate the automated refraction program to complete the full subjective refraction procedure and obtain spherical power, cylindrical power, and cylinder axis.
Senior Optometrist-Operated Automated Subjective Refraction
Diagnostic testA senior optometrist operates the same automated refraction program according to a standardized procedure to obtain spherical power, cylindrical power, and cylinder axis. These measurements serve as the reference results for comparison.
Treatment groups
6
Treatment groupsSee each treatment group below.
Trial outcomes
Primary outcomes
Agreement in refractive prescriptions between operators from different professional backgrounds and senior optometrists using the same automated refraction program
Secondary outcomes
Examination time for comparison operators and senior optometrists using the automated refraction program
Participant acceptance, comfort, and satisfaction with the automated refraction procedure
The questionnaire assesses three aspects: understanding and operation, comfort and visual fatigue, and acceptance and willingness to use. Each item is rated on a 5-point Likert scale from 1 ("strongly disagree") to 5 ("strongly agree"), with higher scores indicating a more favorable evaluation.
Adverse events and ocular discomfort during the examinations