Construction of a Benchmark for Breast Ultrasound AI Interpretation and Performance Evaluation of Multimodal AI Models

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexFemale
Age18-75
SponsorPeking Union Medical College Hospital

About this trial

This single-center, retrospective, observational study aims to construct a standardized benchmark evaluation system for intelligent breast ultrasound image interpretation and to systematically assess the diagnostic performance of current mainstream multimodal artificial intelligence (AI) models.

De-identified B-mode breast ultrasound images with confirmed pathological diagnoses will be retrospectively collected from the institutional archive (2018-2025) and supplemented with images from published open-access datasets. Expert radiologists with varying experience levels will independently annotate all images according to the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) v2025 criteria, including glandular tissue composition, lesion characterization (mass vs. non-mass lesion), morphological descriptors, and final BI-RADS classification.

Baseline deep learning models (CNN-based ResNet-50 and Transformer-based USFM) will be trained to establish performance baselines and to stratify cases by diagnostic difficulty through cross-architecture consensus. Multiple multimodal large language models (MLLMs), including both general-purpose and medical-domain models, will then be evaluated via standardized API calls using BI-RADS-guided chain-of-thought prompts at temperature 0 for reproducibility.

Primary endpoints include BI-RADS classification accuracy and diagnostic AUC for benign-malignant differentiation. Model robustness and safety will be assessed through out-of-distribution rejection testing, temperature-stability experiments, and thinking-mode ablation studies. This study adheres to the FLAIR and TRIPOD-LLM reporting guidelines.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

B-mode breast ultrasound grayscale images from the institutional PACS database or from published open-access breast ultrasound datasets with documented original institutional ethics approval

Image quality adequate for clinical diagnosis with clear visualization of the region of interest

Pathological diagnosis confirmed (for benign and malignant lesion groups), or normal breast status confirmed by a senior radiologist with >15 years of breast ultrasound experience (for the normal group)

Complete de-identification with removal of all personally identifiable information

Disqualifiers

Severely degraded image quality precluding meaningful BI-RADS assessment

Duplicate images from the same patient (only the most representative image retained per lesion)

Images with residual personally identifiable information after de-identification processing

Cases with ambiguous, disputed, or unavailable pathological results

Trial population

De-identified breast ultrasound images from adult patients who underwent breast ultrasound examination at Peking Union Medical College Hospital between 2018 and 2025 with subsequent pathological confirmation, supplemented by images from published, ethics-approved, open-access breast ultrasound datasets (e.g., BUSI, BrEaST).

Trial design

Design model

Cohort

Time perspective

Retrospective

Treatments tested in this trial

  • Multimodal AI Model Diagnostic Evaluation

    Diagnostic test

    Retrospective evaluation of de-identified breast ultrasound images by multiple AI systems, including baseline deep learning models (ResNet-50, USFM) and multimodal large language models, using standardized BI-RADS-guided chain-of-thought prompts via API. No patient contact or clinical decision-making is involved.

Treatment groups

1,380 Participants
are divided into 3 treatment groups
Group A: Normal Breast1 intervention
Group B: Benign Lesion1 intervention
Group C: Malignant Lesion1 intervention

Trial outcomes

Primary outcomes

1

Diagnostic Accuracy for Pathological Diagnosis

Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and F1 score of AI models for benign-malignant classification, with histopathological diagnosis as the gold standard.

Time frame
At study completion, approximately 12 months
2

BI-RADS Classification Accuracy

Overall accuracy of AI models in assigning BI-RADS categories (2, 3, 4A, 4B, 4C, 5) to breast ultrasound images, compared with expert consensus annotation as the reference standard.

Time frame
At study completion, approximately 12 months

Secondary outcomes

1

Agreement with Expert Consensus (Cohen's Kappa)

Cohen's kappa coefficient measuring agreement between each AI model's BI-RADS classification and the expert consensus annotation, reported with 95% confidence intervals.

Time frame
At study completion, approximately 12 months
2

Out-of-Distribution Rejection Rate

Proportion of non-diagnostic images (degraded quality, non-breast ultrasound, other imaging modalities) correctly identified and refused by AI models, evaluating domain safety.

Time frame
At study completion, approximately 12 months
3

Sensitivity, Specificity, PPV, NPV, and F1 Score

Standard diagnostic performance metrics for benign-malignant classification, reported for each AI model individually.

Time frame
At study completion, approximately 12 months

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Peking Union Medical College Hospital

Lead sponsor

Chinese Academy of Medical Sciences

Collaborator