About this trial
The ACCESS-FX+ Registry is a prospective, multicenter, single-arm study designed to evaluate the feasibility of coronary access after transcatheter aortic valve implantation (TAVI) using the Evolut FX Plus transcatheter heart valve in patients with severe aortic stenosis.
TAVI has become an established treatment for patients with severe aortic stenosis across a broad range of surgical risk profiles. As TAVI is increasingly performed in younger patients with longer life expectancy, maintaining access to the coronary arteries after transcatheter heart valve implantation has become an important clinical consideration. A substantial proportion of patients undergoing TAVI have concomitant coronary artery disease and may subsequently require coronary angiography or percutaneous coronary intervention. However, coronary access after TAVI may be challenging because of the spatial relationship between the transcatheter heart valve frame, commissural posts, valve leaflets, and coronary ostia.
Commissural alignment between the native aortic valve and the implanted transcatheter heart valve may play an important role in preserving coronary access. Commissural misalignment may result in a commissural post or valve leaflet being positioned in front of a coronary ostium, potentially interfering with subsequent selective coronary cannulation. In addition to commissural alignment, the geometry and orientation of the transcatheter valve frame relative to the coronary ostia may influence the feasibility of coronary re-access.
The Evolut FX Plus transcatheter heart valve incorporates three enlarged frame cells designed to facilitate coronary access. This modification is intended to increase the likelihood that at least one large cell is favorably positioned relative to each coronary ostium. However, prospective data evaluating selective coronary cannulation through these large cells and the relationship between large-cell orientation, commissural alignment, and coronary anatomy in clinical practice remain limited.
The study will enroll approximately 122 patients aged 65 years or older with severe aortic stenosis undergoing TAVI with the Evolut FX Plus valve. Immediately after valve implantation, selective cannulation of the left and right coronary arteries through the large-cell frame will be attempted using standard diagnostic coronary catheters. The primary endpoint is the successful selective coronary cannulation rate through the Evolut FX Plus large-cell frame, assessed separately for the left and right coronary arteries. Successful selective coronary cannulation is defined as stable engagement of a diagnostic catheter at the coronary ostium allowing coronary contrast injection.
Cardiac computed tomography (CT) performed 3 to 6 months after TAVI will provide a detailed assessment of the spatial relationship between the implanted transcatheter heart valve and the coronary ostia. CT-based assessments will include large cell-to-coronary alignment, alignment between the center of the transcatheter valve leaflet and the coronary ostium, and commissural alignment between the native and transcatheter aortic valves. Follow-up CT will also be used to evaluate findings of valve thrombosis, including leaflet, supravalvular, subvalvular, and sinus hypoattenuation.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients with severe aortic stenosis undergoing TAVI with the Evolut FX Plus transcatheter heart valve.
Age ≥65 years.
Ability and willingness to provide written informed consent for participation in the study.
Disqualifiers
Inability to undergo contrast-enhanced cardiac CT before TAVI.
Anomalous origin of a coronary artery.
Bicuspid aortic valve.
Previous surgical or transcatheter aortic valve replacement.
Trial population
Patients with severe aortic stenosis undergoing TAVI with the Evolut FX Plus transcatheter heart valve.
Trial design
Cohort
Prospective
Treatments tested in this trial
Not listed
Trial groups
Trial outcomes
Primary outcomes
Successful Selective Coronary Cannulation Through the Evolut FX Plus Large-Cell Frame
The proportion of patients in whom successful selective coronary cannulation is achieved through the Evolut FX Plus large-cell frame, assessed separately for the left coronary artery and right coronary artery. Successful selective coronary cannulation is defined as stable engagement of a standard diagnostic catheter at the coronary ostium allowing coronary contrast injection.
Secondary outcomes
Technical Success
Technical success following TAVI with the Evolut FX Plus valve, assessed according to the study protocol and applicable VARC-3 criteria.
Devicel Success
Device success following TAVI with the Evolut FX Plus valve, assessed according to the study protocol and applicable VARC-3 criteria.
Clinical outcomes (Composite of All-Cause Mortality, All Stroke, or Procedure- or Valve-Related Hospitalization)
Composite of All-Cause Mortality, All Stroke, or Procedure- or Valve-Related Hospitalization
CT-based Secondary Outcome (Moderate or Greater Large Cell-to-Coronary Misalignment)
1\) Moderate or Greater Large Cell-to-Coronary Misalignment:: Proportion of patients with moderate or severe large cell-to-coronary misalignment on follow-up cardiac CT. Alignment is determined by the angle between the center of the large cell and the center of the coronary ostium.