About this trial
The "CLEAR-DCB" (Coronary Lesions: European All-comers Registry with DCB) registry.
An open-label, multicenter, observational registry of drug-coated balloon angioplasty in an all-comers population with coronary artery disease.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥18 years at the time of index procedure.
Undergoing PCI with at least one coronary lesion treated with a DCB during the index procedure.
Patient (or legally authorized representative) willing and able to provide written informed procedure consent (unless local regulations permit waiver/retrospective inclusion under appropriate governance).
Disqualifiers
Patients who are unable to provide informed consent and for whom local regulations do not allow retrospective inclusion.
Life expectancy <1 year due to noncardiac comorbidity (advanced malignancy, end-stage liver disease, etc.) where follow-up is unlikely to be feasible.
Enrollment in another investigational study that, in the opinion of the investigator, precludes participation or confounds outcomes (unless both sponsors agree to co-enrollment and data sharing).
Trial design
Single group
Treatments tested in this trial
Drug Coated Balloon
DeviceAll procedures will be performed according to local standard of care and operator judgment. The registry does not mandate use of any particular DCB brand; site operators may use any commercially available DCB (paclitaxel- or sirolimus-based) according to local availability and regulatory approvals. The following recommendations and procedural definitions are provided to harmonize data collection and promote consistent practice across centers (these are guidance only, not prescriptive mandates): Pre-procedural assessment: * Baseline clinical assessment, ECG, and troponin (if ACS). * Diagnostic coronary angiography with careful lesion assessment; intracoronary imaging (IVUS/OCT) is strongly encouraged when available, particularly for ambiguous lesion morphology, left main disease, long lesions, bifurcations, and ISR. Lesion preparation: \- Adequate lesion preparation is crucial for DCB success. Operators should aim for optimal lesion modification with any/all of the following at their d
Treatment groups
Trial outcomes
Primary outcomes
Procedural Success
All of: * Device success \[i. Successful delivery in time and inflation within 30-60 s of the allocated DCB device at the intended target lesion during an attempt with a DCB not previously used (first use), ii. Successful withdrawal of the device system, iii. Attainment of a final in-segment or in-lesion residual stenosis of \<40% with final data reported by core laboratory QCA (preferred methodology)(Post-hoc stratification: optimal result = %DS \<30%; sub-optimal result = 30% ≤ %DS \<40%)\] * Freedom from in-hospital cardiovascular death, target lesion revascularization, peri-procedural myocardial infarction, any stroke, and BARC 3-5 bleeding * Freedom from bail-out stenting (for 'leave-nothing-behind' strategy)
Device Success
All of: * Successful delivery in time and inflation within 30-60 s of the allocated DCB device at the intended target lesion during an attempt with a DCB not previously used (first use) * Successful withdrawal of the device system * Attainment of a final in-segment or in-lesion residual stenosis of \<40% with final data reported by core laboratory QCA (preferred methodology) (Post-hoc stratification: optimal result = %DS \<30%; sub-optimal result = 30% ≤ %DS \<40%)
Major Adverse Cardiovascular Events
Hierarchical occurrence of: 1. All-cause mortality 2. Any MI 3. Any stroke 4. Hospitalization for heart failure 5. Any revascularization
Target Lesion Failure (TLF)
The composite of clinically driven TLR, MI or cardiac death related to the target vessel. Target lesion is the segment where coronary intervention was performed, and the length of the target lesion is inclusive of the arterial segment treated with the stent and the 5mm proximal and 5mm distal to the treated section. Target vessel is the major native coronary artery or bypass graft containing the target lesion. A native coronary artery target vessel includes the arterial segments upstream and downstream from the target lesion and their major side branches. If it cannot be determined with certainty whether an MI or death is related to the target vessel, and at the same time if no other specific reasons can be given, it will be considered as a case of TLF. (balloon length ± 1 mm)
Secondary outcomes
Bleeding
This safety endpoint is defined according to the Bleeding Academic Research Consortium. Major bleeding is defined as Bleeding Academic Research Consortium types 3 and 5. Overt bleeding with hemoglobin drop more than 3 g/dL, any transfusion, procedure-related cardiac tamponade, bleeding requiring surgical intervention or intravenous vasoactive agents and intracranial or intraocular hemorrhage will be recorded as a major bleeding event. Fatal bleeding and subsequent death without no other explainable cause also can be categorized into this class of bleeding.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
National and Kapodistrian University of Athens
Lead sponsor
Tzaneio General Hospital
Collaborator