The objective of this clinical study is to evaluate the safety and effectiveness of the Adagio Medical vCLAS Ventricular Ablation System (including VTS Catheter and Console) in the ablation treatment of Sustained Monomorphic Ventricular Tachycardia (SMVT)

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

IC 1 Male or female ≥ 18 years

IC 2 Patients with a clinical indication for catheter ablation due to ischemic and/or non-ischemic heart disease and recurrent symptomatic sustained scar-mediated monomorphic Ventricular Tachycardia.

Ischemic cardiomyopapthy (ICM) patients with prior history of myocardial infarction with Q waves, focal wall motion abnormality on imaging, fixed perfusion defect correlating with coronary stenosis or prior coronary intervention, 20% ≤ LVEF < 50%.

non-ischemic cardiomyopathy (NICM) patients with scar in a territory without coronary stenosis as evidenced by CMR imaging within the prior 90 days or intra-procedurally using EAM and PES prior to investigational device use, 20% ≤ LVEF < 50%

Disqualifiers

EC 1 Intracardiac thrombus by TTE or TEE within 48 hours prior to the procedure

EC 2 Presence of isolated epicardial scar(s) requiring epicardial ablation identified by either preoperative CMR imaging within 90 days of procedure or intra-procedurally using EAM and PES prior to investigational device use

Idiopathic VT

Automaticity or triggered activity

Trial design

Design model

Single group

Treatments tested in this trial

  • Ultra Low Temperature Ablation (ULTA)

    Device

    ablation procedure using the investigational device (vCLAS Ventricular Ablation System including VTS Catheter and Console)

Treatment groups

100 Participants
are divided into 1 treatment group
Group A: VT CryoablationExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Primary Safety Endpoint - Freedom from definite or probable device or procedure related Major Adverse Events (MAEs) that occur within 7 days following the ablation procedure.

Primary Safety Endpoint is freedom from definite or probable device or procedure related Major Adverse Events (MAEs) that occur within 7 days following the ablation procedure. Events will be adjudicated by an independent Clinical Events Committee (CEC). MAEs include any of the following: • Death • Acute myocardial infarction • Cardiac perforation/pericardial tamponade • Cerebral infarct or systemic embolism • Major bleeding requiring transfusion • Acute Mitral, Tricuspid or Aortic valve damage resulting in moderate or severe regurgitation • Access site complications requiring medical or surgical intervention • Pericarditis • Heart block requiring a permanent pacemaker • Other serious adverse device effects (SADEs), including TIAs, adjudicated by an independent Clinical Events Committee (CEC) to be probably or definitely related to the Adagio System.

Time frame
7 days following the ablation procedure
2

Primary Efficacy Endpoint - Freedom from recurrent sustained MMVT in the absence of a new AAD or increase in dose of a pre-ablation AAD for VT management at 6 months following the ablation procedure

Primary Efficacy Endpoint is defined as freedom from recurrent sustained MMVT in the absence of a new AAD or increase in dose of a pre-ablation AAD for VT management at 6 months following the ablation procedure, where sustained MMVT is defined as continuous MMVT for \> 30 seconds (programmed monitoring zone only), or MMVT requiring appropriate ICD intervention regardless of duration. All ICD interrogation reports will be adjudicated by an independent VT Event Committee (VTEC) to support the primary efficacy endpoint.

Time frame
6 months after the procedure
3

Primary Procedural Endpoint - Percentage of non-inducibility VT targeted for ablation post-procedure

Primary Procedural Endpoint is defined as non-inducibility of any VT targeted for ablation at the end of the procedure

Time frame
at the end of the ablation procedure

Secondary outcomes

1

Secondary Safety Endpoint - Freedom from definite or probable device or procedure related Serious Adverse Events (SAEs) within 12 months following the ablation procedure

Secondary Safety Endpoint is defined as freedom from definite or probable device or procedure related Serious Adverse Events (SAEs) within 12 months following the ablation procedure. Events will be adjudicated by an independent Clinical Events Committee (CEC).

Time frame
12-months post ablation procedure
2

Secondary Efficacy Endpoint - Freedom from VT greater than 30 seconds or appropriate ICD intervention at 12 months

Secondary Efficacy Endpoint is defined as freedom from Ventricular Tachycardia lasting longer than 30 seconds or appropriate ICD intervention at 12 months

Time frame
12-months post ablation procedure

Other outcomes