CT Quantitative Assessment of Interstitial Lung Disease

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18-90
SponsorAssiut University

About this trial

Interstitial lung disease (ILD) refers to a broad category of heterogeneous lung diseases with different etiologies and features characterized by inflammation and fibrosis of the lung parenchyma and manifested as exertional dyspnea, interstitial patterns on high resolution computed tomography (HRCT), and abnormal pulmonary function tests (PFTs) The aim of this study is to investigate is there any correlation between changes seen in the lung parenchyma by HRCT and the pulmonary functions of the patients.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Diagnosis of ILD (based on clinical, radiological, and pulmonary function criteria +/- histopathological criteria).

Availability of CT chest DICOM images and pulmonary function test results (within a 2-weeks period from each other).

Disqualifiers

Pregnancy

Pulmonary edema.

Primary pulmonary hypertension;

Chronic obstructive pulmonary disease

Trial population

The study population will consist of consecutive patients diagnosed with ILD recruited from the pulmonary clinic or inpatient service. The diagnosis of ILD will be based on American Thoracic Society/European Respiratory Society (ATS/ERS) classification system for ILD.

Trial design

Design model

Case-only

Time perspective

Prospective

Treatments tested in this trial

  • High resolution CT Chest

    Diagnostic test

    CT chest in our institution will be done with standard high resolution protocol . No I.V contrast will be given. Scans will be obtained during full inspiration in supine position from the thoracic inlet to the level of the diaphragm. Patients with CT chest performed outside our institution will be reviewed in DICOM format and assessed for its compatibility to be integrated into the computer-based analysis software.

  • Spirometry

    Diagnostic test

    Spirometry will be performed using standard techniques according to ATS-ERS criteria 2019 . Spirometry device (Zan 300, NSPIRE HEALTH GMBH Co.) will be used. Percentage predicted values (%pred) will be calculated based on reference values for healthy adults. All patients will be required to undergo spirometry in a reproducible way, and the best values will be reported. Spirometry should meet international acceptability and repeatability standards

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

CT visual Warrick score (measured by points)

Warrick score is calculated as follow : A point value will be given to each abnormality i.e ground-glass appearance (areas of hazy opacity in the lung that do not obscure the underlying bronchial structures) = 1, irregular pleural margins = 2, septal/subpleural lines = 3, honeycombing (usually 3-10 mm in diameter and have thick walls) = 4, and subpleural cysts = 5. In each patient, the "severity of disease" score will be obtained by adding single point values (maximal severity score 15). An "extent of disease" score is obtained by counting the number of bronchopulmonary segments involved for each abnormality as follows ; one to three segments scored as 1, four to nine segments scored as 2, and more than nine segments scored as 3 (maximal extent score 15). The severity and extent of disease will be then calculated as the total Warrick score (range from 0 to 30)

Time frame
baseline
2

Total lung volume, Volume of lung occupied by low attenuation areas, Volume of lung occupied by high attenuation areas, Volume of normal lung areas and volume of consolidation areas

Total lung volume , volume of the lung occupied by low attenuation areas (attenuation values from -1024 to -950 HU; representing emphysema), volume of normally attenuated lung (from -949 to -700 HU; corresponds to healthy lung tissue) and volume of the lung occupied by high attenuation areas (between - 699 and - 250 HU) ; it represents the lung parts which are more dense than healthy lung); volume of lung with density from -249 to +40 HU, this group corresponds to areas with further increase in density, including the semi-consolidation and consolidation.

Time frame
baseline
3

Percentage of the lung occupied by low attenuation areas, percentage of normal lung, percentage of the lung occupied by high attenuation areas and percentage of consolidation areas.

Percentage of the lung occupied by low attenuation areas (attenuation values from -1024 to -950 HU), percentage of normal lung (from -949 to -700 HU), percentage of the lung occupied by high attenuation areas (between - 699 and - 250 HU) and percentage of consolidation areas (from -249 to +40 HU) in each lung and in each lobe.

Time frame
baseline
4

Mean lung density of each lung, both lungs and every lobe in Hounsfield unit (HU)

Mean lung density of each lung , both lungs and each lung lobe (e.g., upper, middle, and lower lobes) will be measured in Hounsfield unit (HU).

Time frame
baseline

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: