Deep Learning Detection of Pulmonary Hypertension and Low Ejection Fraction Via Digital Stethoscope and 3-Lead ECG

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorEko Devices, Inc.

About this trial

This is a prospective, observational study evaluating whether heart sounds (phonocardiograms) and three-lead electrocardiograms (ECGs) recorded using the Eko CORE 500 digital stethoscope can help detect pulmonary hypertension (PH) and low left ventricular ejection fraction (EF ≤ 40%). PH is a condition characterized by high blood pressure in the pulmonary arteries, which can lead to heart failure and carries significant risks if undiagnosed. Low EF, which indicates reduced pumping ability of the heart, is also associated with increased risk of severe cardiac events but can remain undetected because patients often have no symptoms or only nonspecific symptoms.

In this study, adults undergoing clinically indicated echocardiograms or right heart catheterization at outpatient sites will be invited to participate. Participants will complete a single study session lasting about 20 minutes, during which heart sounds and a three-lead ECG will be collected using the Eko CORE 500 device. If participants have had a clinical 12-lead ECG within 30 days of their echocardiogram or right heart catheterization, those data may also be used for analysis. A clinically indicated echocardiogram or right heart catheterization (RHC) performed within seven days before or after the Eko CORE 500 recording will serve as the reference standard to confirm the presence or absence of PH and low EF.

Up to 3,850 participants may be enrolled across multiple sites to ensure that approximately 3,500 complete the study. The data collected will be used to develop and validate artificial intelligence (AI) algorithms that aim to detect PH and identify low EF, potentially enabling earlier and simpler screening for these conditions in clinical practice.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Adults aged 18 years and older

Able and willing to provide informed consent

Completed a clinical echocardiogram or right heart catheterization within 7 days before or after study procedures

Disqualifiers

Unwilling or unable to provide informed consent

Patients who are hospitalized

Patients undergoing echocardiography with a limited echocardiogram (does not apply to patients undergoing right heart catheterization)

Trial population

This study will enroll adult patients (18 years and older) who are undergoing clinically indicated transthoracic echocardiography or right heart catheterization. Participants must be able and willing to provide informed consent and must complete a clinical echocardiogram or right heart catheterization within 7 days before or after the study procedures. Patients who are hospitalized, unable or unwilling to provide informed consent, or who are undergoing a limited echocardiogram will be excluded.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Eko CORE 500 Digital Stethoscope

    Device

    The FDA-cleared Eko CORE 500 digital stethoscope is used to collect phonocardiogram (PCG) and three-lead ECG recordings from participants. This observational study uses these recordings to develop and validate artificial intelligence algorithms to detect pulmonary hypertension and low left ventricular ejection fraction. No modifications to the device or device functionality are being tested.

Treatment groups

3,850 Participants
are divided into 1 treatment group
Group A: All Participants1 intervention

Trial outcomes

Primary outcomes

1

Sensitivity and specificity of the deep-learning algorithm for detecting pulmonary hypertension (PH)

The primary outcome is the diagnostic performance of the algorithm developed from Eko CORE 500 recordings to detect pulmonary hypertension, as confirmed by clinical echocardiography or right heart catheterization. Sensitivity and specificity will be calculated by comparing algorithm predictions to the echocardiogram or right heart catheterization gold standard.

Time frame
Up to 24 months

Secondary outcomes

1

Algorithm Diagnostic Performance for Detection of Low Ejection Fraction

To evaluate the diagnostic accuracy of the Eko algorithm in detecting low ejection fraction (EF), measured by area under the receiver operating characteristic (ROC) curve (AUC), positive predictive value (PPV), and negative predictive value (NPV).

Time frame
Through study completion, 2 years

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.