About this trial
This mixed-methods study will include retrospective model development, cross-sectional validation, and prospective clinical validation. The study will generally follow relevant guidelines for AI-based clinical research.
1. Retrospective Model Development
Approximately 300,000 gastroscopy examinations from our center will be retrospectively included. Available endoscopic data and related clinical information will be collected for model development and internal validation.
Several publicly available gastrointestinal endoscopy datasets will also be included to increase data diversity. These datasets will provide supplementary data for model development and evaluation.
The model will broadly support common gastroscopy-related tasks, such as lesion assessment, examination quality evaluation, and report generation. General data cleaning, quality control, and expert review will be conducted when necessary. 2. Cross-sectional Validation
Approximately 70,000 gastroscopy examinations from a different time period will be consecutively included for independent validation.
The model results will be compared with reference results established according to generally accepted clinical practice. Diagnostic standards will broadly follow relevant clinical guidelines and expert judgment.
The purpose of this phase is to assess the model's overall diagnostic performance, report quality, generalizability, and stability using commonly accepted evaluation methods. 3. Prospective Clinical Validation
A prospective clinical validation study involving approximately 1,000 patients will be conducted at our center.
The model will be integrated into routine clinical practice to provide general assistance to physicians. Its outputs will be used for reference and will not replace physicians' final clinical decisions or signed reports.
The study will generally compare clinical workflows with and without AI assistance. It will assess the model's potential effects on work efficiency, workload, clinical usability, and safety under real-world conditions.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
None
Disqualifiers
Patients undergoing specialized endoscopic procedures, such as endoscopic ultrasonography or endoscopic retrograde cholangiopancreatography (ERCP)
Trial population
Individuals who are at least 18 years of age, are undergoing a routine gastroscopy, and have provided informed consent to participate in this study
Trial design
Cohort
Other
Treatments tested in this trial
Retrospective Model Development Cohort
Other interventionThis cohort includes approximately 300,000 patients who underwent gastroscopy. Retrospectively collected gastroscopy images, videos, and corresponding endoscopy reports will be used for the development, training, and internal validation of multimodal, multitask artificial intelligence models. No study-specific interventions will be administered to patients.
Cross-Sectional Validation Cohort
Other interventionThis cohort includes approximately 70,000 patients who underwent gastroscopy. Gastroscopy images, videos, and corresponding reports will be used to independently evaluate the diagnostic performance, video quality assessment, and report generation capabilities of the developed AI models. Model outputs will be compared with expert-established reference standards. No study-specific interventions will be administered to patients.
Prospective Clinical Evaluation Cohort
Other interventionThis cohort will include approximately 1,000 patients undergoing gastroscopy. The developed AI system will be evaluated in real-world clinical workflows. The study will assess report generation efficiency, clinical acceptability, physician workload, and safety by comparing AI-assisted reporting with conventional physician reporting. Final endoscopy reports will be reviewed and signed by physicians.
Treatment groups
Trial outcomes
Primary outcomes
[email protected]:0.95
For the lesion-detection task, average precision is calculated at 10 intersection-over-union thresholds ranging from 0.50 to 0.95 in increments of 0.05, and the mean of these 10 values is reported. Double-blind annotations from senior endoscopists are used as the reference standard. This indicator evaluates the model's overall lesion-detection and localization performance across a range of overlap criteria. A higher [email protected]:0.95 indicates more accurate and robust lesion detection.
Clinical Acceptability of Automatically Generated Reports
The outcome is defined as the proportion of AI-generated reports receiving a Likert score of ≥4 on a five-point scale, where 1 indicates "completely unusable" and 5 indicates "ready for direct issuance." Three blinded senior endoscopists independently rate each report, and the modal rating is used as the final score. This indicator measures the proportion of AI-generated reports considered clinically usable with little or no revision. A higher acceptability rate indicates better clinical applicability of the report-generation system.
Secondary outcomes
Number of Physician Modifications
The number of additions, deletions, and revisions made by the physician is extracted from the system's backend logs. This indicator measures the extent of physician intervention required to finalize an AI-generated report. Fewer modifications indicate that the generated report is more accurate, complete, and clinically usable.
Cohen's Kappa for Video Quality Assessment
The model's video quality assessments are compared with experts' subjective ratings, and Cohen's kappa is calculated to assess agreement in image clarity, exposure, field-of-view completeness, and other quality dimensions. This indicator measures chance-adjusted agreement between the model and expert endoscopists. A higher kappa value indicates stronger agreement.
Sensitivity
Model outputs are classified as positive or negative using a prespecified clinically relevant threshold. Sensitivity is calculated as the number of true-positive lesions correctly identified by the model divided by the total number of positive lesions according to the reference standard. This indicator measures the model's ability to detect patients or lesions with the target condition. A higher sensitivity indicates a lower false-negative rate.
NASA-TLX Total Workload Score
The NASA-TLX questionnaire is used to evaluate six dimensions: mental demand, physical demand, temporal demand, performance, effort, and frustration. The dimension scores are combined into a weighted total score. This indicator measures physicians' perceived workload when preparing endoscopy reports. A lower score under the AI-assisted condition indicates that the system reduces physician workload.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.