Device Impact on the Efficacy of Serum Product Study

ConditionSkin Wrinkles
Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexFemale
Age25-55
SponsorChinaNorm

About this trial

The goal of this clinical trial is to learn whether combining a beauty device with the test product affects skin parameters in women troubled by wrinkles. It aims to evaluate the impact of the beauty device on the efficacy of the test product. The main questions it aims to answer are:

\- Does the combination of the beauty device plus test product achieve better skin improvement compared with using the test product alone?

Researchers will compare beauty device + test product applied to one half of the face and one side of the neck against the test product alone applied to the contralateral half-face and neck, to see whether the beauty device enhances the efficacy of the test product.

Participants will:

* Receive randomized split-face and split-neck treatment during the study * Attend 10 scheduled study visits * Undergo standardized image capture, clinical assessment and instrumental skin measurement

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

1. Chinese female with 25 - 55 years old.

2. All skin types, 50% self-declare sensitive skin.

3. Self- declare with concerns on facial wrinkle problems.

4. The difference in clinical grading between the two sides of the face should be less than one point.

Disqualifiers

1. Pregnant or breast-feeding woman or woman planning pregnancy during the study.

2. Subject deprived of rights by a court or administrative order.

3. Major subject to a guardianship order.

4. Subject residing in a health or social care establishment.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Beauty device combined with test skincare product

    Combination product

    Short-term: 1.48 g test product applied on half-face \& half-neck, massaged by beauty device for about 5 min 50 sec at study site. Long-term: Subjects follow standardized home skincare routine between visits. On-site visits: treatment side receives beauty device and test product.

  • Test skincare product alone

    Other intervention

    Short-term: 0.45 g test product manually applied on half-face by staff, no beauty device. Long-term: same full-face home skincare routine. On-site visits: only test product is applied on this control side without beauty device treatment.

Treatment groups

35 Participants
are divided into 2 treatment groups
Group A: Arm 1Experimental treatment 1 intervention
Group B: Arm 2Active comparator 1 intervention

Trial outcomes

Primary outcomes

1

Dermatologist clinical assessment of skin parameters using modified Griffiths 10-point scale

A dermatologist evaluates skin parameters on the left and right half-face/half-neck separately. Assessments include skin tone, skin quality and wrinkle parameters graded on a 0-9 scale. Half-point (0.5) or incremental values (0.4/0.6) may be used. The rater is blinded to prior scores after baseline.

Time frame
2 weeks before baseline, Baseline, 1 hour and 24 hours after product application, 1 hour after product application at Week 1 visit, 1 hour after product application at Week 2 visit,1 hour after product application at Week 3 visit and Week 4 visit.

Secondary outcomes

1

Stratum corneum hydration measured by Corneometer® CM 825

Skin hydration is measured bilaterally on cheeks using Corneometer® CM 825 (capacitance method). The mean value of 3 consecutive valid readings is recorded; higher values indicate greater hydration.

Time frame
Baseline, Week1 visit, Week2 visit, Week3 visit, Week4 visit
2

Transepidermal water loss (TEWL) measured by Vapometer

TEWL is measured bilaterally on cheeks using Vapometer. One reading is taken per site. Unit: g/m²h; lower values indicate better skin barrier function.

Time frame
Baseline, Week1 visit, Week2 visit, Week3 visit, Week4 visit
3

wrinkle analysis using Antera 3D

Antera 3D generates 3D colour images of skin surface by analysing shadow and light reflection. Standard wrinkle photographs are captured and analysed.

Time frame
Baseline, 1 hour after product application, Week3 (1 hour after product application at Week3 visit), Week4
4

Skin texture analysis using VisioScan VC20

VisioScan VC20 (UV CCD imaging probe) captures skin images on bilateral cheeks and neck. Images are processed and analysed by SELS software to evaluate skin smoothness.

Time frame
Baseline, 1 hour and 24 hours after product application, Week1 (visit and 1h post-application), Week2 (visit and 1h post-application), Week3 (visit and 1h post-application), Week4

Other outcomes

1

3D facial imaging using Vectera-H2

Handheld Vectera-H2 captures 180° stereophotogrammetric 3D facial images. Assessment endpoint: facial fullness.

Time frame
Baseline, 1 hour after product application, Week3 (1 hour after product application at Week3 visit), Week4
2

Facial imaging acquisition using VISIA®-CR (Canfield)

Facial images are captured by trained staff with VISIA®-CR, equipped with multiple light sources (standard, cross-polarized, parallel polarized, oblique, UV). Images are taken from left, central and right views with subject wearing hairnet and eyes closed.

Time frame
Baseline, 1 hour and 24 hours after product application, Week1 (visit and 1h post-application), Week2 (visit and 1h post-application), Week3 (visit and 1h post-application), Week4

Sponsors and contacts

Click on the lead sponsor to view all of their trials.