About this trial
Misplacement of endotracheal tube (ETT) can have devastating complications for patients, some of which include respiratory failure, atelectasis, and pneumothorax.
There are a number of ways to verify the correct placement of ETT, with the stethoscope auscultation being commonly used despite its low accuracy (60-65%) in distinguishing tracheal from bronchial intubation (4-6). The gold standard techniques include Chest X Ray or fiberoptic bronchoscope (7-8), with a recent study showing point-of-care ultrasound. However, these techniques are expensive, time-consuming, often not readily available and require substantial training before users can reliably utilize them. Given intubation is often performed in urgent clinical settings, a technique that can reliably yet efficiently localize ETT would be beneficial.
Tele-auscultation system via Core stethoscope (Eko, Berkeley, CA) has been shown to be effective in identifying pathologic heart murmur (10) yet its potential use in guiding the correct placement of ETT has not been explored. We set out to study the suitability of Core stethoscope in detecting the correct placement of ETT.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Any patients under the age of 18
Surgery requiring an ETT
Consent/parental consent to
Disqualifiers
Possible difficult airway
Significant lung pathology
with any major cardiac anomaly
Trial design
Single group
Treatments tested in this trial
Eko CORE Stethoscope
DeviceEko CORE stethoscope will be used as a visual and auditory means of confirming placement of ETT
Point of care ultrasound
DevicePoint of care ultrasound will be used as a means of confirming placement of ETT. This is the "gold standard" used in standard of care
Treatment groups
Trial outcomes
Primary outcomes
Localization of endotracheal tube placement by the presence/absence of lung pleural linings movement by ultrasound
Ultrasound placed vertically on the anterior chest of a patient will assess for the presence/absence of the horizontal movement of the two lung pleural linings with respiration.
Localization of endotracheal tube placement by the presence/absence of breath sounds detected by Core-Eko augmented stethoscope
Presence of breath sounds will be assessed and recorded using Core-Eko augmented stethoscope, in conjunction with the smartphone interface over Bluetooth, by auscultating patient's chest. The technology will display breath sounds as a visual soundwave on the smartphone. As a result, this will be used to determine location of endotracheal tube (for example, if breath sounds absent in the left lung, we would infer that the tube is in the right bronchus).