About this trial
This study develops an end-to-end Vision Transformer (ViT)-based artificial intelligence system for ultrasound-based diagnosis of placenta accreta spectrum (PAS), aiming to improve the accuracy and efficiency of prenatal screening using standardized ultrasound video inputs.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Pregnant women aged between 18 and 45 years;
Gestational age between 24 and 34 weeks;
Pregnant women with a history of placenta previa;
Pregnant women with an anterior placenta;
Disqualifiers
Failure to provide written informed consent;
Presence of severe complications that precluded continuation of pregnancy;
Inability to comply with study procedures for other reasons.
Trial population
Pregnant women aged 18-45 years; Gestational age between 24 and 34 weeks; Pregnant women with a history of placenta previa or with an anterior placenta.
Trial design
Other
Prospective
Treatments tested in this trial
Vision Transformer-Based End-to-End Ultrasound Artificial Intelligence Model
Diagnostic testAn end-to-end ultrasound AI model based on the Vision Transformer (ViT) architecture was developed for the diagnosis of placenta accreta spectrum (PAS) using standardized ultrasound video inputs. Ultrasound Video Acquisition Protocol: With the patient in the supine position, the operator scanned the lower abdomen using a conventional grayscale probe. Video recording was performed in gray-scale mode for approximately 20-30 seconds, ensuring that the entire scanning region from the lower uterine segment to the uterine fundus was comprehensively captured.
Treatment groups
Trial outcomes
Primary outcomes
Diagnostic performance of the end-to-end Vision Transformer (ViT)-based ultrasound AI model for placenta accreta spectrum (PAS)
Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic curve (AUC) of the model.
Secondary outcomes
Clinical Feasibility of the Standardized Ultrasound Video Recording Method
Completion Rate (Proportion of patients who successfully complete the standardized recording) and time consumption (Mean recording time)
Consistency and Efficiency Between the AI Model and Physician Diagnosis
Diagnostic Consistency: Kappa coefficient used to evaluate the consistency between the AI model's diagnoses and those of experienced ultrasound physicians (Kappa \> 0.75 indicates good agreement).
Safety of the AI Model
False Negative Rate: Proportion of missed PAS-positive patients and the impact on patient outcomes .
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
FANG HE
Lead sponsor
The Third Affiliated Hospital of Guangzhou Medical University
Sponsor institution