About this trial
The goal of this study is to investigate the feasibility of using intravenous fluorescein during a standard endoscopy-along with a laser to activate it and an optical filter-to identify changes in the duodenal mucosa after a controlled food challenge in individuals with IBD and IBS who experience food intolerances. The main questions it aims to answer are:
* Is this technique feasible approach to assess food intolerances in patients with IBD and IBS? * Does patients with IBD and IBS exhibit acute tissue changes upon exposure to specific food antigens?
Researches will compare the food antigen to a placebo solution (saline solution without an antigen) to see if the reaction in the tissue is different.
Participants will:
* Answer questionnaires. * Provide a blood and stool sample. * Take an allergy test. * Undergo an upper endoscopy.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Confirmed diagnosis of IBD (UC or CD) and under clinical remission for at least 3 months, OR confirmed diagnosis of IBS (any subtype) by Rome IV criteria.
Report having one or more food intolerance.
Able to provide informed consent.
Disqualifiers
Presence of a known food allergy.
Presence of serum IgE positivity or a positive skin-prick test to cow's milk.
Known allergy to fluorescein.
Diagnosis of celiac disease.
Trial design
Parallel
Treatments tested in this trial
Upper diagnostic endoscopy with food challenges and biopsies
Diagnostic testParticipants will undergo an upper gastrointestinal endoscopy under conscious sedation. Standard monitoring will be used, and a high-definition video system will record the procedure. A Fuji colonoscope fitted with a transparent distal cap and optical filter will guide the examination up to the proximal jejunum. Upon reaching the duodenum (D3), 5 mL of 10% fluorescein and 40 mg methylscopolamine will be injected intravenously. Immediately after, either a cow's milk protein solution or a placebo solution will be applied to the duodenal mucosa via the endoscope channel. A laser will excite the fluorescein, and real-time video will be recorded. Duodenal fluid (1-1.5 mL) will be collected with an ERCP catheter, and eight biopsies will be obtained for analysis
Treatment groups
Trial outcomes
Primary outcomes
Procedure completition
Successful completion of the procedure including sample collection, administration of the food challenge, and development of a reaction in the duodenal mucosa. A positive reaction in the mucosa will be defined by the presence of intraepithelial lymphocytes \>25/100 epithelial cells.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: