About this trial
This study is testing a new retinal implant called the HARP4K Retinal Prosthesis System in people with severe vision loss caused by advanced retinal diseases, including age-related macular degeneration and retinitis pigmentosa. Up to five participants will receive the implant and be followed to assess its safety and how well it works. The main aim of the study is to determine whether the device and the implantation procedure can be used safely. The study will also explore whether the implant may help improve vision and quality of life. The information collected will help researchers decide whether the device should be evaluated in a larger future clinical study.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Is between 60 and 90 years old at the date of inclusion;
Has a confirmed diagnosis of geographic atrophy due to AMD in both eyes;
Has best corrected visual acuity of the study eye of LogMAR 1.3 (20/400; NCT03333954) or worse measured by ETDRS (less than 22 letters);
Has an atrophic patch in the study eye including the fovea of at least the implant size (>= 6 mm in minimum diameter);
Disqualifiers
Has a highly myopic study eye (>26 mm AP);
Has a highly hyperopic study eye (<21 mm AP);
Has a refraction of study eye higher than + 4 dpt or lower than - 4 dpt for patients with IOL;
Has no light perception in either eye;
Trial design
Single group
Treatments tested in this trial
Subretinal implantation of HARP4K retinal prosthesis
DeviceParticipants will undergo surgical implantation of the HARP4K Retinal Prosthesis System in the subretinal space of the worse-seeing eligible eye. The investigational system comprises a retinal implant containing approximately 4,000 stimulation microelectrodes, external eyeglasses providing wireless power and communication, and a computer-based fitting console. Following postoperative recovery, the device will be activated and individually configured to deliver electrical stimulation to surviving retinal neurons.
Treatment groups
Trial outcomes
Primary outcomes
Device and procedure safety related event
Incidence proportion of device-related and procedure related adverse events and serious adverse events occurring from implantation through 18months followup.
Secondary outcomes
Change in Visual Function
Visual function will be assessed with the implant "ON" vs. "OFF" using Basic Light Localization and Motion Test (BaLM).
Change in Visual Acuity
Change in visual acuity will be measured with the implant "ON" vs "OFF" using Tumbling E test, Grating Acuity and Contrast Grating.
Change in Activities of Daily Living
Changes in daily life situations such as navigation and object recognition including faces will be assessed in a real-world environment with the implant "ON" vs "OFF".
Questionnaires
Questionnaires for Patient Report Outcome.