Study of the BioRISE Biolimus Drug-Coated Balloon Versus the SELUTION SLR Sirolimus-Coated Balloon in De Novo Coronary Lesions, With a Single-Arm In-Stent Restenosis Cohort (SUNRISE)

Trial statusNot yet recruiting
Trial phaseEarly Phase 1
Trial typeInterventional
Biological sexAll
Age18+
SponsorBiosensors Europe SA

About this trial

Coronary heart disease causes narrowing of the heart (coronary) arteries (arteries are blood vessels, which supply oxygen-rich blood to the heart muscle). Your heart specialist will have explained to you that they suspect that you have a narrowing in one or more of your heart arteries. This narrowing may be causing you to have chest pains or evidence of reduced blood supply to your heart muscle.

One commonly used treatment for this problem is to stretch the narrowing with a balloon and then insert a small mesh-like device called a stent, which will hold the artery open, improving the blood flow to your heart, and thereby help with your symptoms. An alternative treatment is to open the narrowing with a balloon that is coated with an anti-inflammatory drug (so called drug-coated balloon) as treatment instead of a stent. Drug-coated balloons are used to reduce the risk of re-narrowing of your coronary arteries without leaving an implant (like a stent) behind. A stent (which is a foreign object that does not belong in the body) can cause vessel inflammation and it bears the risk of blockage within the stent (in-stent restenosis or ISR). Drug-coated balloons leave no implant behind but target the narrowing in your vessel wall with the delivery of an anti-inflammatory agent to the vessel wall, allowing the blood vessel to heal.

Biosensors has developed a balloon coated with a drug called Biolimus A9™ which suppresses inflammation in the artery where the narrowing has occurred. We refer to this balloon coated with Biolimus A9™ as BA9-DCB (Biolimus A9™ drug-coated balloon) also known as BioRISE. This device is not commercially available and will be tested in this study for the first time in humans. However, several coronary stents made by Biosensors are already on the market that contain the Biolimus A9™ drug. It has been proven to be safe and effective in preventing re-narrowing of the artery where the stent is placed.

In this study, two types of drug-coated balloons (DCBs) will be used; the BioRISE (test group; group 1) and SELUTION SLR, a balloon that is coated with sirolimus (control group; group 2). The SELUTION SLR balloon is commercially available in Europe.

The study has the following design:

• Patients will be treated according to standard hospital procedures using the study device.

The study has the following design:

* Patients will be treated according to standard hospital procedures using the study device. * There will be two different types of patients included in this study. * 400 patients with a narrowing in a heart artery that has never been treated before (referred to as de novo disease), of whom 200 will be treated with the BioRISE balloon and 200 with the SELUTION SLR balloon. The allocation to the two possible treatments is random as it must be in a study like this. Of these 400 patients, 15 in each treatment arm, will have the inside of the artery imaged during the procedure using a well-established technique called Optical Coherence Tomography (OCT) and Quantitative Flow Ratio (QFR) * 43 patients with a narrowing inside a stent that was implanted in the past (referred to as in-stent restenosis). In these patients, only the BioRISE balloon will be used. * Your doctor will explain to which category applies to you. * There will be up to 25 hospitals taking part in the study in the UK, and in up to 5 European countries * Patients will be taking part in the study for up to 3 years, and during this time their health status will be assessed by telephone or hospital visit at 1month, 9 month, 12 months, 24 months and 36 months. * There will be a check up angiography to assess the primary end point at 9 months for all participants.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

None

Disqualifiers

Age ≥ 18 years

Documented angina and/or a positive functional ischaemia test, unstable angina, or a stabilized NSTEMI presentation. Patients undergoing index PCI of a non-culprit lesion after AMI may be included in the absence of further documented ischaemia/angina.

Female subjects of childbearing potential have a negative pregnancy test ≤ 7 days before the procedure or are using a contraceptive device or drug.

Eligible for and willing to comply with dual antiplatelet therapy (DAPT).

Trial design

Design model

Parallel

Treatments tested in this trial

  • Biolimus A9 Drug Coated Balloon

    Device

    Interventions in BioRISE arm aim to improve coronary luminal diameter for the treatment of de novo lesions well as lesions resulting from In-Stent Restenosis

  • SELUTION SLR

    Device

    The comparator applies to the de novo randomised cohort only; the single-arm ISR cohort has no comparator.

Treatment groups

443 Participants
are divided into 2 treatment groups
Group A: BioRISE Biolimus Drug-Coated BalloonExperimental treatment 1 intervention
Group B: SELUTION SLR sirolimus-coated balloonActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

In-segment Late Lumen Loss (LLL) at 9 months

The primary endpoint is in-segment late lumen loss at 9 months, defined as the difference between the post-procedural minimal lumen diameter (MLD) and the 9-month follow-up MLD, measured by quantitative coronary angiography (QCA) and assessed by an blinded angiographic core laboratory (ARC-DCB Table 1, item 8). Analysis segment: in-segment, defined for this study as the balloon-treated segment plus 5 mm proximal and 5 mm distal, consistent with the comparator's pivotal trials (SELUTION DeNovo). ARC-DCB defines in-segment as the treated segment plus 1 mm, the ARC-DCB rationale for in-segment analysis (a proximal and distal buffer zone mitigating geographic miss= applies equally. The core laboratory additionally reports in-segment LLL with the ARC-DCB 1 mm margins.

Time frame
9 months

Secondary outcomes

1

Secondary outcomes

Device-Oriented Composite Endpoint (DOCE) at all time points Lesion-Oriented Composite Endpoint (LOCE) at 30 days Target Lesion Failure (TLF) at all timepoints Target Vessel Failure (TVF) at all timepoints Target-vessel MI (ARC-DCB) at all timepoints. All-cause mortality and cardiovascular death (per ARC-2 as adopted by ARC-DCB). Any myocardial infarction (Fourth and Fifth Universal Definition of Myocardial Infarction). Peri-procedural myocardial infarction (ARC-DCB) at discharge and 30 days. Any stroke (ischaemic, haemorrhagic or undetermined; Neuro-ARC) at all timepoints. Any defined lesion thrombosis. All TLR, TVR and non-TVR (ARC-DCB) at all timepoints. BARC 3-5 bleeding (BARC \[34\], as adopted by ARC-DCB) at discharge, 30 days and 1 year Binary restenosis (\> 50% diameter stenosis in the target segment at follow-up by QCA; ARC-DCB). Device success Procedural success

Time frame
• index procedure • Discharge up to 7 days (patient and hospital practice dependent) • 30 days • 9 months • 1 year • 2 years • 3 years

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: