About this trial
The objective of this study is to provide a regional, mechanistic characterization of pulmonary ventilation changes following treatment with the Apreo BREATHE System, using hyperpolarized ¹²⁹Xe MRI, in BREATHE-3 participants. BREATHE-Xe is designed to generate mechanistic signals regarding whether airway scaffolds reduce ventilation defects, improve gas exchange, and correlate with CT and spirometric/plethysmographic changes observed in BREATHE-3. Findings support mechanistic interpretation and future hypothesis generation.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Enrolled and randomized in BREATHE-3 to the Treatment arm or enrolled as a Control arm participant who has elected crossover treatment following BREATHE-3 Month 12.
Separate written BREATHE-Xe informed consent obtained prior to any sub-study procedures.
Able to perform coached breath-hold maneuvers of ≥10 seconds, as assessed by the site investigator.
Willing and able to travel to KUMC or UAB for all scheduled Xe-MRI sessions.
Disqualifiers
Any absolute contraindication to MRI, including ferromagnetic implants not approved for MRI, cardiac pacemaker or ICD not MRI-conditional, cochlear implants, severe claustrophobia, or any condition judged incompatible with safe MRI by the investigator.
Known allergy or hypersensitivity to xenon gas or components of the HP ¹²⁹Xe formulation. 3. SpO₂ <88% at rest on the day of planned Xe-MRI, measured on the participant's usual oxygen (room air or standard supplemental oxygen per BREATHE-3 protocol or site standard of care). Supplemental oxygen is removed only for the preparation breaths and xenon inhalation, then resumed.
Trial design
Single group
Treatments tested in this trial
Hyperpolarized Xenon MRI
DrugHyperpolarized Xenon MRI (HP ¹²#Xe) is a radiation-free imaging technique that boosts signal strength to create high-resolution images of how gas moves through the lungs. By tracking inhaled gas across separate breath-holds, it measures airflow blockage, tissue transfer efficiency, and gas uptake by red blood cells, while a washout test maps how well the lungs clear gas. It has been applied to characterize pulmonary impairment in COPD and emphysema and to detect regional ventilation changes following bronchoscopic interventions.
Apreo BREATHE Airway Scaffold
DeviceThe experimental treatment involves placement of up to 6 Apreo BREATHE Airway Scaffolds (up to 3 per lung), in a single procedure using bronchoscopy and fluoroscopy. Treatment group subjects will also receive optimal medical management (OMM). The BREATHE Airway Scaffold implant procedure occurs under the BREATHE-3 main study. This procedure is not part of the BREATHE-Xe study, which focuses on changes in regional ventilation.
Treatment groups
Trial outcomes
Primary outcomes
Primary Endpoint
The primary endpoint is the within-participant change in whole-lung VDP from baseline to Month 6, summarized descriptively. Ventilation defect percentage (VDP) will be defined as the percentage of total lung volume with ¹²⁹Xe signal intensity below 60% of the whole-lung mean signal intensity. A reduction in VDP is consistent with improvement in regional ventilation distribution following treatment. Given the small sample size, the median change will be reported as the primary summary measure, with the mean, 95% confidence interval, SD, and range also reported. No success threshold will be applied.
Secondary outcomes
Ventilation
Change in whole-lung VDP
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Apreo Health, Inc.
Lead sponsor
University of Alabama at Birmingham
Collaborator
University of Kansas Medical Center
Collaborator