Edge-to-edge Mitral Valve Repair in ATTR-CM

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorMedical University of Vienna

About this trial

No previous study has evaluated the effectiveness of transcatheter edge-to-edge mitral valve repair (TEER) in patients with ATTR-associated cardiomyopathy (ATTR-CM) and significant mitral regurgitation, as this specific patient population was specifically excluded from previous large TEER trials. From a pathophysiological perspective, effective treatment of significant regurgitant volume and consecutive improvement of forward volume appears highly desirable in a condition with intrinsically low output. However, whether this translates into improved functional capacity, better quality of life, and better clinical outcomes compared to conservative heart failure management alone remains to be investigated.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Proven ATTR-CM

Significant symptomatic MR (3+ or 4+ by independent echocardiographic core laboratory assessment)

Subject has been adequately treated per applicable standards, including for coronary artery disease and heart failure (e.g., diuretics)

New York Heart Association (NYHA) functional class II, III, or ambulatory IV

Disqualifiers

AL-associated cardiomyopathy

Aortic valve disease requiring surgery or transcatheter intervention

Severe right ventricular dysfunction

Hemodynamic instability requiring inotropic support or mechanical heart assistance

Trial design

Design model

Parallel

Treatments tested in this trial

  • TEER

    Device

    Transcatheter edge-to-edge mitral valve repair under general anaesthesia with transoesophageal echocardiographic and fluoroscopic guidance; up to three newer-generation MitraClip (NTR, XTR; Abbott) or PASCAL (Edwards Lifesciences) devices to maximally reduce mitral regurgitation. Intraprocedural invasive haemodynamic measurements before and after device deployment.

  • Optimal Medical Therapy

    Other intervention

    Optimal medical therapy according to the current understanding of heart failure management in ATTR-CM (careful volume management, rate/rhythm control in atrial fibrillation, anticoagulation where indicated). ATTR-specific therapy (e.g. tafamidis, acoramidis) is allowed but not mandatory in both arms at the discretion of the treating physician; all heart failure and ATTR-specific medication is recorded at every visit.

Treatment groups

106 Participants
are divided into 2 treatment groups
Group A: InterventionalExperimental treatment 2 interventions
Group B: ControlActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

Hierarchical composite of all-cause mortality, cumulative frequency of unplanned cardiovascular-related hospitalizations, change from baseline in 6-minute walk distance, and change from baseline in KCCQ Overall Summary score through month 12

Each subject in the TEER+OMT group is compared with each subject in the OMT group in a pairwise manner, within strata defined by National Amyloidosis Centre disease stage (I, II, III) at baseline, in hierarchical order: (1) all-cause mortality (heart transplantation, combined heart-liver transplantation and implantation of a durable mechanical cardiac-assist device count as death); (2) cumulative frequency of unplanned cardiovascular-related hospitalizations, compared over the shorter follow-up time of the pair; (3) change from baseline in 6-minute walk distance, a difference of ≥30 m defining a win (smaller differences are ties); (4) change from baseline in the Kansas City Cardiomyopathy Questionnaire Overall Summary score (0-100, higher = better health status), a difference of ≥5 points defining a win. Statistical significance is tested with the Finkelstein-Schoenfeld method at a two-sided alpha of 0.05; the win ratio quantifies the treatment effect.

Time frame
12 months

Secondary outcomes

1

Change from baseline in NT-proBNP (key secondary endpoint)

Change from baseline in N-terminal pro-B-type natriuretic peptide (pg/mL), analysed with a mixed-effects model for repeated measures / analysis of covariance with treatment group and visit as fixed effects and the baseline value as covariate.

Time frame
Baseline, 6 months and 12 months
2

Technical, device, and procedural success of TEER (in the TEER group only)

Technical, device, and procedural success of TEER as defined according to the definitions of the Mitral Valve Academic Research Consortium (MVARC)

Time frame
Technical success at exit from the procedure room; device and procedural success at 6 and 12 months

Other outcomes

1

Change from baseline in echocardiographic indices of myocardial performance and remodelling

Change from baseline in left ventricular ejection fraction, forward stroke volume, global longitudinal strain, tissue Doppler-derived systolic and diastolic velocities and diastolic function indices, left atrial strain, myocardial contraction fraction (left ventricular stroke volume/myocardial volume) and left ventricular stroke work index, assessed by a blinded echocardiographic core laboratory.

Time frame
Baseline, 6 months and 12 months
2

Acute intraprocedural change in invasive haemodynamics (TEER group only)

Change in forward stroke volume, cardiac output and cardiac index, right atrial pressure, pulmonary artery pressures, pulmonary capillary wedge pressure, and pulmonary and systemic vascular resistance measured with standard catheterization laboratory equipment immediately before and after device deployment. Sub-analyses will assess cut-offs of acute haemodynamic change that identify responders with regard to myocardial performance and clinical outcome.

Time frame
Intraprocedural (immediately before and after device deployment)

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Medical University of Vienna

Lead sponsor

Austrian Science Fund (FWF)

Collaborator