About this trial
Endotracheal tube cuff pressure outside the recommended range of 20-30 cmH₂O is common in routine anesthesia practice. Over-inflation can injure the tracheal mucosa, while under-inflation increases the risk of aspiration and ventilator-associated pneumonia. This prospective, single-center, uncontrolled before-and-after study evaluates whether a brief educational intervention improves cuff pressure management in the operating room. Adult patients undergoing general anesthesia with endotracheal intubation at Marmara University Pendik Training and Research Hospital are enrolled in two consecutive periods. In both periods, cuff pressure is measured with a calibrated manometer shortly after intubation, together with the professional role and clinical experience of the provider who inflated the cuff. Between the two periods, a two-minute educational video explaining the importance of optimal cuff pressure and demonstrating manometer use is distributed to all operating room staff involved in cuff inflation, and reminder posters are placed in every operating room. The primary outcome is the proportion of cuff pressure measurements within the recommended range before versus after the intervention. The secondary outcome is the association between the cuff-inflating provider's role and experience and cuff pressure appropriateness. No change to patient care beyond the educational intervention is made.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Adult patients aged 18 years or older
Elective or emergency surgery under general anaesthesia
Orotracheal intubation with a cuffed endotracheal tube
Written informed consent
Disqualifiers
Laparoscopic surgery (pneumoperitoneum alters cuff pressure)
Use of nitrous oxide during anaesthesia (diffusion into the cuff alters cuff pressure)
Nasotracheal intubation or use of a supraglottic airway device
Patients already intubated on arrival to the operating room
Trial design
Single group
Treatments tested in this trial
Brief educational intervention (educational video and reminder posters)
BehavioralA two-minute educational video explaining the importance of maintaining endotracheal tube cuff pressure within 20-30 cmH₂O, summarising complications of over- and under-inflation, and demonstrating the use of a cuff manometer, distributed via an institutional messaging group to all operating room staff involved in cuff inflation (anaesthesia technicians, resident and specialist physicians). Reminder posters emphasising optimal cuff pressure were displayed in all operating rooms during the post-intervention period. The intervention was directed at healthcare providers, not at patients.
Treatment groups
Trial outcomes
Primary outcomes
Proportion of patients with endotracheal tube cuff pressure within the recommended range (20-30 cmH₂O)
Endotracheal tube cuff pressure measured once by an investigator with a calibrated aneroid cuff manometer (VBM Medizintechnik, Germany) after tube fixation, with the patient supine and before surgical positioning, without informing the provider who inflated the cuff. A pressure of 20-30 cmH₂O is classified as appropriate. The proportion of patients with an appropriate cuff pressure is compared between the pre- and post-intervention periods and expressed as a risk ratio, odds ratio, and absolute difference in proportions with 95% confidence intervals.
Secondary outcomes
Association between the cuff-inflating provider's professional role and clinical experience and cuff pressure appropriateness
Proportion of patients with an appropriate cuff pressure (20-30 cmH₂O) according to the professional role of the provider who inflated the cuff (anesthesia technician, resident physician, or specialist physician) and their years of clinical experience (\<2, 2-5, or \>5 years), analyzed within each study period and with both periods pooled, and in multivariable logistic regression adjusted for study period, body mass index, and tracheal tube size.
Sponsors and contacts