Effect of CPAP on 6-Minute Walk Test Outcomes in Patients With ECAC

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorBeth Israel Deaconess Medical Center

About this trial

The purpose of this protocol is to perform a prospective, randomized, double-blinded, pacebo-controlled clinical trial to determine the influence of a non-invasive positive pressure ventilation device on exercise capacity and symptoms in adult patients with ECAC. Primary outcome will include the total distance traversed by the study subject during a standard 6-minute walk test, and secondary outcomes will include peak flow measurement and symptom reporting before and after the exercise testing. The study will focus on the use of continuous positive airway pressure (CPAP) device. CPAP is FDA-approved for the treatment of various medical conditions, including obstructive sleep apnea and heart failure, but is not FDA-approved for the treatment of ECAC. The study will enroll 32 ambulatory study subjects with confirmed ECAC at the BIDMC, and each study subject will be monitored for up to 3 months.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patient with a diagnosis of ECAC either via bronchoscopy or CT Scan

Age > 18 years

Patients that will undergo a diagnostic or therapeutic bronchoscopy as part of their standard of care

Patients with a baseline 6 MWT

Disqualifiers

Patients with poorly-controlled respiratory comorbidities (asthma, COPD, obstructed sleep apnea, GERD, relapsing polychondritis)

No evidence for acute respiratory tract infection, or respiratory tract infection within the prior 3 weeks

Resting bradycardia (<50 beats/min), frequent multifocal PVCs, complex ventricular arrhythmia, sustained SVT

Dysrhythmia that might pose a risk during exercise or training

Trial design

Design model

Parallel

Treatments tested in this trial

  • Continuous positive airway pressure (CPAP) device

    Device

    Use of a CPAP during a 6 minute walk test to maintain the airways open during the respiratory cycle

  • Sham-continuous positive airway pressure (CPAP) device

    Device

    An enlarged air leak incorporated into the exhalation valve will be positioned between the mask and the CPAP tubing, allowing airflow resistance of the exhalation port to be almost eliminated by increasing its area, thereby virtually cancelling positive pressure. Also an orifice restrictor in the CPAP circuit will be connected between the CPAP unit and the tubing in order to load the blower with the same airflow resistance as in true CPAP.

Treatment groups

32 Participants
are divided into 2 treatment groups
Group A: Group 1Experimental treatment 1 intervention
Group B: Group 2Sham comparator 1 intervention

Trial outcomes

Primary outcomes

1

Difference in meters walked in 6MWTs

Statistical difference between the 6 MWT results of the CPAP and sham-CPAP groups as compared with the initial results of the 6 MWT and between groups using ANCOVA.

Time frame
3 months

Secondary outcomes

1

Modified Borg scale scores for dyspnea

Time frame
3 months
2

Modified Borg scale scores for exertion

Time frame
3 months
3

Subjective assestment of cough during 6MWTs

Time frame
3 months

Other outcomes