About this trial
The objective of this randomized clinical trial is to evaluate and compare the effect of four different residual adhesive removal techniques following orthodontic bracket debonding on postoperative tooth hypersensitivity. The study compares low-speed tungsten carbide burs against fiberglass burs, white stone burs, and rubber-impregnated polishing points. Postoperative hypersensitivity will be evaluated using a Visual Analogue Scale (VAS) with an air-blast stimulus test immediately after debonding, at 24 hours, and at 7 days follow-up.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Patients of any gender aged 15 to 45 years undergoing routine fixed labial orthodontic bracket removal across anterior and premolar teeth in both jaws.
Systemically healthy patients.
Good oral hygiene with a healthy, intact periodontium without clinical attachment loss or gingival recession.
Patients capable of reliably recording subjective discomfort on a Visual Analogue Scale (VAS) and willing to attend follow-up visits.
Disqualifiers
Active use of systemic analgesics, NSAIDs, corticosteroids, or centrally acting pain medications within 14 days prior to debonding.
Use of desensitizing toothpastes, mouthwashes, or topical fluoride varnishes within 30 days prior to the trial.
Heavy bruxism, clenching habits, or pathological wear/erosion extending into dentin.
Pregnant or lactating female patients.
Trial design
Parallel
Treatments tested in this trial
Low-Speed Tungsten Carbide Bur
DeviceComposite resin is removed using a 12-fluted tapered low-speed tungsten carbide bur operated at 15,000-20,000 rpm under continuous air-water spray irrigation until all visible adhesive remnant is completely eliminated.
Fiberglass Bur
DeviceComposite resin remnants are eliminated using a fiberglass resin-removal bur operated at 15,000-20,000 rpm under continuous air-water spray irrigation until all visible material is completely removed.
White Stone Bur
DeviceComposite resin remnants are removed using a fine-grit Arkansas white stone bur (aluminum oxide) operated at 10,000-15,000 rpm under continuous air-water spray irrigation until the enamel surface is clear.
Rubber-Impregnated Polishing Point
DeviceResidual adhesive tags are removed and polished using a rubber-impregnated composite polishing point operated at 10,000-15,000 rpm under continuous air-water spray irrigation
Treatment groups
Trial outcomes
Primary outcomes
Postoperative Hypersensitivity
Patient-reported pain and hypersensitivity evaluated using a Visual Analogue Scale (VAS) score ranging from 0 (No pain) to 10 (Unbearable severe pain) in response to a 2-second dental syringe air-blast stimulus test.
Secondary outcomes
Procedure Time
Time taken to perform complete residual adhesive removal per tooth, measured using a stopwatch
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Asmaa Badr Abdelfatah
Lead sponsor
Cairo University
Sponsor institution
This trial is not recruiting at the moment. You can still explore other options: