About this trial
Oxytocin is a key hormone that regulates uterine contractions during labor. Dural Puncture Epidural Analgesia (DPEA) is a modern technique for labor pain relief that provides faster onset and more reliable analgesia than standard epidural.While it is known that neuraxial analgesia can suppress oxytocin levels, it is unclear whether this effect depends on the stage of labor at which analgesia is administered. This prospective comparative study will enroll 120 pregnant women in spontaneous labor who request DPEA, divided into two groups: Early group (cervical dilation≤5 cm, n=60) and Late group (cervical dilation≥6 cm , n=60). Both groups receive identical DPEA (a total volume of 15 mL containing 0.1% bupivacaine and 100 µg fentanyl is administered through the epidural catheter, following dural puncture with a 26G spinal needle without intrathecal drug injection). The primary outcome is the percentage change in plasma oxytocin from baseline (T-0, before analgesia) to T-Eff (30 minutes after onset of effective analgesia defined as VAS\<2). Patients who received any exogenous oxytocin (induction or augmentation) before T-0 are excluded to ensure that the measured oxytocin represents endogenous production. The study will contribute to understanding how the timing of neuraxial analgesia relative to labor progression affects the endogenous oxytocin system, with potential implications for optimal clinical timing of labor analgesia administration.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Gestational age 37-41 weeks, singleton pregnancy, vertex presentation
Spontaneous onset of labor (not induced)
Request for neuraxial labor analgesia (DPEA)
Cervical dilation ≤5 cm (Early Group) or ≥ 6 cm (Late Group) at the time of DPEA
Disqualifiers
Any administration of exogenous oxytocin (induction or augmentation) prior to T-0 blood sampling
Use of misoprostol, dinoprostone, or other labor-stimulating agents
Opioid use within the preceding 12 hours
Membrane rupture >2 hours before enrollment
Trial population
Pregnant women aged 18-40 years admitted to the Labor Ward of Ankara Bilkent City Hospital with spontaneous labor who request Dural Puncture Epidural Analgesia (DPEA). Participants will be classified according to cervical dilation at the time of DPEA request as Early Labor Group (≤5 cm) or Late Labor Group (≥6 cm). Eligible participants will have a singleton, vertex pregnancy at 37-41 weeks of gestation and ASA physical status II.
Trial design
Cohort
Prospective
Treatments tested in this trial
Dural Puncture Epidural Analgesia (DPEA)
Procedure/SurgeryStandard clinical DPEA procedure: Combined spinal-epidural kit used to locate epidural space at L3-L4 or L4-L5 with 17G Tuohy needle (loss of resistance). A 26G spinal needle is passed through the Tuohy needle to perform dural puncture; CSF return is confirmed. NO intrathecal drug is administered. The spinal needle is withdrawn, the epidural catheter is advanced 5 cm into the epidural space. After negative aspiration and test dose, 15 mL of 0.1% bupivacaine is administered through the epidural catheter. Maintenance analgesia is provided via patient-controlled epidural analgesia (PCEA).
Dural Puncture Epidural Analgesia (DPEA)
Procedure/SurgeryStandard clinical DPEA procedure: Combined spinal-epidural kit used to locate epidural space at L3-L4 or L4-L5 with 17G Tuohy needle (loss of resistance). A 26G spinal needle is passed through the Tuohy needle to perform dural puncture; CSF return is confirmed. NO intrathecal drug is administered. The spinal needle is withdrawn, the epidural catheter is advanced 5 cm into the epidural space. After negative aspiration and test dose, 15 mL of 0.1% bupivacaine is administered through the epidural catheter. Maintenance analgesia is provided via patient-controlled epidural analgesia (PCEA).
Treatment groups
Trial outcomes
Primary outcomes
Percentage change in maternal plasma oxytocin concentration from baseline to T-Eff
Calculated as: \[(T-Eff plasma oxytocin - T-0 plasma oxytocin) / T-0 plasma oxytocin\] × 100. Positive values indicate an increase in oxytocin; negative values indicate suppression. Plasma oxytocin concentration will be measured in pg/mL using an enzyme-linked immunosorbent assay (ELISA).
Secondary outcomes
Time to effective analgesia (VAS<2). (VAS: Visual analogue scale 0-10 poits. 10 means worst pain)
Duration in minutes from DPEA injection to the first time point when patient reports VAS pain score \<2. (VAS: Visual analogue scale 0-10 poits. 10 means worst pain)
Cervical dilation progression rate
Rate of cervical dilation in cm/hour from DPEA administration to delivery.
Bromage motor block score
Degree of motor block assessed by Bromage scale (0=no block, 3=complete block).
Need for post-T-Eff oxytocin augmentation
Binary outcome: whether exogenous oxytocin was initiated after T-Eff for labor augmentation (yes/no), start time, and initial dose
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: