Effect of Dural Puncture Epidural Analgesia on Oxytocin in Early vs Late Labor

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexFemale
Age18-40
SponsorAnkara City Hospital Bilkent

About this trial

Oxytocin is a key hormone that regulates uterine contractions during labor. Dural Puncture Epidural Analgesia (DPEA) is a modern technique for labor pain relief that provides faster onset and more reliable analgesia than standard epidural.While it is known that neuraxial analgesia can suppress oxytocin levels, it is unclear whether this effect depends on the stage of labor at which analgesia is administered. This prospective comparative study will enroll 120 pregnant women in spontaneous labor who request DPEA, divided into two groups: Early group (cervical dilation≤5 cm, n=60) and Late group (cervical dilation≥6 cm , n=60). Both groups receive identical DPEA (a total volume of 15 mL containing 0.1% bupivacaine and 100 µg fentanyl is administered through the epidural catheter, following dural puncture with a 26G spinal needle without intrathecal drug injection). The primary outcome is the percentage change in plasma oxytocin from baseline (T-0, before analgesia) to T-Eff (30 minutes after onset of effective analgesia defined as VAS\<2). Patients who received any exogenous oxytocin (induction or augmentation) before T-0 are excluded to ensure that the measured oxytocin represents endogenous production. The study will contribute to understanding how the timing of neuraxial analgesia relative to labor progression affects the endogenous oxytocin system, with potential implications for optimal clinical timing of labor analgesia administration.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Gestational age 37-41 weeks, singleton pregnancy, vertex presentation

Spontaneous onset of labor (not induced)

Request for neuraxial labor analgesia (DPEA)

Cervical dilation ≤5 cm (Early Group) or ≥ 6 cm (Late Group) at the time of DPEA

Disqualifiers

Any administration of exogenous oxytocin (induction or augmentation) prior to T-0 blood sampling

Use of misoprostol, dinoprostone, or other labor-stimulating agents

Opioid use within the preceding 12 hours

Membrane rupture >2 hours before enrollment

Trial population

Pregnant women aged 18-40 years admitted to the Labor Ward of Ankara Bilkent City Hospital with spontaneous labor who request Dural Puncture Epidural Analgesia (DPEA). Participants will be classified according to cervical dilation at the time of DPEA request as Early Labor Group (≤5 cm) or Late Labor Group (≥6 cm). Eligible participants will have a singleton, vertex pregnancy at 37-41 weeks of gestation and ASA physical status II.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Dural Puncture Epidural Analgesia (DPEA)

    Procedure/Surgery

    Standard clinical DPEA procedure: Combined spinal-epidural kit used to locate epidural space at L3-L4 or L4-L5 with 17G Tuohy needle (loss of resistance). A 26G spinal needle is passed through the Tuohy needle to perform dural puncture; CSF return is confirmed. NO intrathecal drug is administered. The spinal needle is withdrawn, the epidural catheter is advanced 5 cm into the epidural space. After negative aspiration and test dose, 15 mL of 0.1% bupivacaine is administered through the epidural catheter. Maintenance analgesia is provided via patient-controlled epidural analgesia (PCEA).

  • Dural Puncture Epidural Analgesia (DPEA)

    Procedure/Surgery

    Standard clinical DPEA procedure: Combined spinal-epidural kit used to locate epidural space at L3-L4 or L4-L5 with 17G Tuohy needle (loss of resistance). A 26G spinal needle is passed through the Tuohy needle to perform dural puncture; CSF return is confirmed. NO intrathecal drug is administered. The spinal needle is withdrawn, the epidural catheter is advanced 5 cm into the epidural space. After negative aspiration and test dose, 15 mL of 0.1% bupivacaine is administered through the epidural catheter. Maintenance analgesia is provided via patient-controlled epidural analgesia (PCEA).

Treatment groups

120 Participants
are divided into 2 treatment groups
Group A: Early Labor Group1 intervention
Group B: Late Labor Group1 intervention

Trial outcomes

Primary outcomes

1

Percentage change in maternal plasma oxytocin concentration from baseline to T-Eff

Calculated as: \[(T-Eff plasma oxytocin - T-0 plasma oxytocin) / T-0 plasma oxytocin\] × 100. Positive values indicate an increase in oxytocin; negative values indicate suppression. Plasma oxytocin concentration will be measured in pg/mL using an enzyme-linked immunosorbent assay (ELISA).

Time frame
From T-0 (immediately before DPEA) to T-Eff (30 minutes after onset of effective analgesia defined as VAS<2); total duration approximately 35-45 minutes depending on time to VAS<2. (VAS: Visual analogue scale 0-10 poits. 10 means worst pain)

Secondary outcomes

1

Time to effective analgesia (VAS<2). (VAS: Visual analogue scale 0-10 poits. 10 means worst pain)

Duration in minutes from DPEA injection to the first time point when patient reports VAS pain score \<2. (VAS: Visual analogue scale 0-10 poits. 10 means worst pain)

Time frame
Within 30 minutes of DPEA administration
2

Cervical dilation progression rate

Rate of cervical dilation in cm/hour from DPEA administration to delivery.

Time frame
From DPEA to delivery (variable, typically 1-6 hours)
3

Bromage motor block score

Degree of motor block assessed by Bromage scale (0=no block, 3=complete block).

Time frame
At delivery
4

Need for post-T-Eff oxytocin augmentation

Binary outcome: whether exogenous oxytocin was initiated after T-Eff for labor augmentation (yes/no), start time, and initial dose

Time frame
From T-Eff to delivery

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: