Effect of Individualized Positive End-expiratory Pressure (PEEP) in Patients Who Have an Intrinsic PEEP During One-lung Ventilation

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age19-100
SponsorSamsung Medical Center

About this trial

This study investigates the effects of three extrinsic PEEP settings-5 cmH2O, 0 cmH2O, and an individualized PEEP (70% of the measured intrinsic PEEP)-on intrinsic PEEP and hemodynamic stability in patients with intrinsic PEEP undergoing lung resection surgery, using a randomized, crossover design.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

American Society of Anesthesiologists Physical Status I - III

The Eastern Cooperative Oncology Group Performance Status Grade 0 - 2

Lung resection surgery requiring one-lung ventilation for over 60 minutes

Indication of double-lumen endobronchial tube (female 35 Fr, male 37 Fr)

Disqualifiers

Large bullae

Emergency surgery

Mechanical ventilation before surgery

Hemodynamic instability before surgery

Trial design

Design model

Single group

Treatments tested in this trial

  • PEEP0

    Procedure/Surgery

    PEEP 0 (zero) means off-PEEP on the anesthesia machine.

  • PEEP5

    Procedure/Surgery

    PEEP5 means setting the PEEP to 5 cmH2O on the anesthesia machine.

  • PEEPi

    Procedure/Surgery

    PEEPi (individualized PEEP) means setting the PEEP to 70% of intrinsic PEEP on the anesthesia machine.

Treatment groups

48 Participants
are divided into 1 treatment group
Group A: Experimental groupExperimental treatment 3 interventions

Trial outcomes

Primary outcomes

1

Intrinsic positive end-expiratory airway pressure

During one-lung ventilation, each patient will randomly receive three PEEP interventions: 0 cmH2O, 5 cmH2O, and the 70% value of intrinsic PEEP. After each 5-minute intervention, intrinsic PEEP will be measured by the anesthesia machine.

Time frame
During a 30-minute period from the start of one-lung ventilation to the completion of the intervention
2

Stroke volume

During one-lung ventilation, each patient will randomly receive three PEEP interventions: 0 cmH2O, 5 cmH2O, and the 70% value of intrinsic PEEP. After each 5-minute intervention, Stroke volume will be measured by an arterial pressure-based cardiac output monitor.

Time frame
During a 30-minute period from the start of one-lung ventilation to the completion of the intervention

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.