About this trial
Laryngeal masks are widely used supraglottic airway devices, but their cuffs differ considerably in shape and design. The cuff exerts pressure on the pharyngeal structures, which may provoke a physiological stress response and contribute to postoperative pharyngeal complaints. This prospective, randomized, two-centre trial compares three commercially available laryngeal masks with different cuff designs (SaCoVLM, LMA Supreme and Ambu AuraGain) in 162 adult patients undergoing elective surgery under general anaesthesia. Anaesthesia induction is standardized and guided by State Entropy, and cuff pressure is standardized to 40-50 cmH2O in all groups. The primary outcome is the change in mean arterial pressure after laryngeal mask insertion. Secondary outcomes include heart rate, nociception and depth-of-anaesthesia indices (Surgical Pleth Index, Response Entropy - State Entropy difference), insertion characteristics, oropharyngeal leak pressure and postoperative pharyngolaryngeal complaints up to 24 hours. The hypothesis is that cuff shape modifies the stress exerted on the pharynx and thereby influences the patient's stress response.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18-80 years
ASA physical status I-II
Scheduled for elective surgery under general anaesthesia with a laryngeal mask airway indicated
No history or predictors of difficult airway
Disqualifiers
Refusal to sign informed consent
ASA physical status III or higher
Emergency surgery
Laparoscopic surgery
Trial design
Parallel
Treatments tested in this trial
SaCoVLM video laryngeal mask
DeviceAirway secured with the SaCoVLM video laryngeal mask (second-generation supraglottic airway device with integrated video channel), inserted after induction of general anaesthesia according to the manufacturer's instructions.
LMA Supreme
DeviceAirway secured with the LMA Supreme (second-generation supraglottic airway device), inserted after induction of general anaesthesia according to the manufacturer's instructions.
Ambu AuraGain
DeviceAirway secured with the Ambu AuraGain (second-generation supraglottic airway device), inserted after induction of general anaesthesia according to the manufacturer's instructions.
Treatment groups
Trial outcomes
Primary outcomes
Maximum Percentage Change in Mean Arterial Pressure From Baseline
Haemodynamic stress response to laryngeal mask insertion: maximum percentage change in mean arterial pressure (MAP) from the pre-insertion baseline value (measured under standardized anaesthesia at State Entropy 40-60) across the post-insertion measurement points. A between-group difference of 10% of baseline MAP is considered clinically relevant.
Secondary outcomes
Postoperative Sore Throat Intensity
Intensity of sore throat assessed by the patient on a visual analogue scale (VAS, 0-100 mm; 0 = no pain, 100 = worst imaginable pain).
Incidence of Postoperative Sore Throat
Presence of sore throat reported by the patient (yes/no).
Change in Heart Rate From Baseline
Heart rate (beats/min) as a marker of the haemodynamic stress response to laryngeal mask insertion; change from the pre-insertion baseline value.
Incidence of Hoarseness
Presence of hoarseness (yes/no).
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Masarykova Nemocnice v Usti nad Labem, Krajska Zdravotni a.s.
Lead sponsor
Jan Evangelista Purkyne University in Usti nad Labem, Faculty of Health Studies
Collaborator
This trial is not recruiting at the moment. You can still explore other options: