About this trial
* The aim of this study is to assess the impact of transcutaneous electrical stimulation on polysomnographic findings in obstructive sleep apnea patients. * The hypothesis of the present study is that nocturnal delivery of transcutaneous electrical stimulation of the pharyngeal dilators, in particular the genioglossus, may help in treating the functional loss of the neuromuscular tone with sleep onset to keep the Upper airway patent during sleep which would reduce the severity of OSA as measured by the apnea-hypopnea-index (AHI), so representing an alternative and better-tolerated approach compared to usual care with CPAP.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
None
Disqualifiers
Patients with central sleep apnea or predominantly central sleep-disordered breathing.
Patients with significant unstable cardiovascular or respiratory disease that may increase the risk of participation.
Patients with implanted electronic devices, such as pacemakers or implantable cardioverter-defibrillators.
Patients with skin lesions, infection, irritation, or other abnormalities at the intended electrode application sites.
Trial design
Single group
Treatments tested in this trial
Transcutaneous Electrical Stimulation
DeviceTranscutaneous electrical stimulation will be delivered using an EV-906 Digital TENS/EMS device. Two 4 × 4 cm electrode patches will be placed bilaterally over the submental region, approximately halfway between the chin and the angle of the mandible. Stimulation will use a pulsed, symmetric, biphasic waveform at a frequency of 30 Hz and a phase duration of 200 microseconds, with 5-second ON and 5-second OFF cycles. Stimulation intensity will be titrated while the participant is awake to establish a tolerable sensory level. The intervention will be administered during the second overnight polysomnography session to assess its effects on polysomnographic parameters in patients with obstructive sleep apnea.
Treatment groups
Trial outcomes
Primary outcomes
Change in Apnea-Hypopnea Index (AHI)
The change in the apnea-hypopnea index (AHI), defined as the number of apneas and hypopneas per hour of sleep, between baseline overnight polysomnography performed without electrical stimulation and the second overnight polysomnography performed during active transcutaneous electrical stimulation. AHI will be compared between the two sessions to evaluate the acute effect of electrical stimulation on OSA severity.
Secondary outcomes
Change in Oxygen Desaturation Index (ODI)
The change in oxygen desaturation index (ODI), defined as the number of oxygen desaturation events per hour of sleep, between baseline polysomnography without electrical stimulation and polysomnography performed during active transcutaneous electrical stimulation.
Change in Sleep Efficiency
The change in sleep efficiency, calculated as total sleep time divided by total recording time in bed and expressed as a percentage, between baseline polysomnography and polysomnography performed during active transcutaneous electrical stimulation.