About this trial
This single-group interventional study investigates the safety and physiologic effects of functional electrical stimulation (FES) applied to the tongue and submental muscles in adults at high risk for sleep apnea. Participants will receive five stimulation frequencies (15, 25, 35, 45, and 75 Hz) in randomized order during a single visit. Ultrasound and tongue pressure (IOPI) measurements, as well as subjective assessments of discomfort and perceived effects, will be conducted before, during, and after stimulation. The primary objective is to evaluate changes in muscle thickness, length, and tongue strength across different stimulation frequencies. Secondary objectives include assessing participant discomfort, safety, and subjective treatment effects.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Adults aged 19 years or older
STOP questionnaire score ≥ 2
Able to read and write in Korean
Voluntarily provides written informed consent to participate in the study
Disqualifiers
Refusal to undergo study procedures or failure to provide informed consent
Cognitive impairment or psychiatric disorders that interfere with the ability to follow study instructions
Pregnant or breastfeeding women
Known allergy or hypersensitivity to electrical stimulation pads or related materials (e.g., silicone, polypropylene, polyethylene)
Trial design
Single group
Treatments tested in this trial
Functional Electrical Stimulation Device
DeviceA functional electrical stimulation device is applied to the submental region using surface adhesive electrodes. Stimulation is delivered at five different frequencies (15, 25, 35, 45, and 75 Hz) in randomized sequence during a single study visit. Each frequency is administered within the same session to evaluate immediate physiologic responses of the tongue muscles. Participants are blinded to the stimulation frequency applied during each condition.
Treatment groups
Trial outcomes
Primary outcomes
Change in genioglossus muscle thickness measured by ultrasonography
The thickness of the genioglossus muscle is measured using ultrasonography before and immediately after electrical stimulation at each frequency (15, 25, 35, 45, and 75 Hz) during a single study visit.
Change in genioglossus muscle length measured by ultrasonography
The length of the genioglossus muscle is measured using ultrasonography before and immediately after electrical stimulation at each frequency (15, 25, 35, 45, and 75 Hz) during a single study visit.
Change in tongue strength measured by the Iowa Oral Performance Instrument (IOPI)
Tongue strength is measured using the Iowa Oral Performance Instrument (IOPI) in kilopascals (kPa) before electrical stimulation and immediately after completion of all frequency conditions during a single study visit (\~1 hour). IOPI scores range from 0 kPa (no measurable pressure) to approximately 70 kPa (maximum tongue strength), with higher scores indicating greater tongue strength.
Secondary outcomes
Participant-reported discomfort associated with electrical stimulation
Participant discomfort is assessed using a 1-5 Likert scale questionnaire during each stimulation frequency and immediately after completion of all frequency conditions during the study visit (\~1 hour). Scale interpretation: 1 = very uncomfortable, 2 = uncomfortable, 3 = neutral, 4 = comfortable, 5 = very comfortable. Higher scores indicate greater comfort.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Seoul National University Bundang Hospital
Lead sponsor
National Research Foundation of Korea
Collaborator