About this trial
This study will compare two fresh gas flow rates during general anesthesia in adults undergoing lumbar stabilization surgery while lying face down. Fresh gas flow is the rate at which oxygen and other gases are supplied to the anesthesia breathing system. Lower flow rates may reduce anesthetic use and its environmental impact, but their effects on breathing during prolonged surgery need further evaluation.
Eighty six adults will be randomly assigned to receive a fresh gas flow rate of either 0.3 or 2 liters per minute. Both groups will receive sevoflurane anesthesia and standardized mechanical ventilation.
The main outcome is the percentage change in dynamic respiratory system compliance, a measure of how easily the lungs and chest expand during ventilation, between 10 and 120 minutes after reaching the assigned flow rate. Other assessments will include breathing mechanics, blood oxygen and carbon dioxide levels, brain oxygenation, lung ultrasound findings, postoperative oxygen needs, pulmonary complications, and hospital length of stay. Anesthetic and fresh gas consumption, anesthetic cost, and estimated greenhouse gas emissions will also be compared. Fresh gas flow will be increased if predefined safety criteria are met.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18 years or older.
Scheduled for elective lumbar stabilization surgery in the prone position.
American Society of Anesthesiologists (ASA) physical status I-III.
Body mass index below 40 kg/m².
Disqualifiers
ASA physical status IV or higher.
Body mass index of 40 kg/m² or higher.
Known pulmonary disease.
Declining to participate or not providing written informed consent.
Trial design
Parallel
Treatments tested in this trial
Minimal Fresh Gas Flow at 0.3 L/min
Other interventionFresh gas flow will be reduced to 0.3 L/min after prone positioning and confirmation of hemodynamic and ventilatory stability. Sevoflurane will be administered using automated controlled anesthesia to target approximately 1 minimum alveolar concentration. The assigned flow will be maintained unless predefined rescue criteria require an increase in fresh gas flow.
Fresh Gas Flow at 2 L/min
Other interventionFresh gas flow will be set at 2 L/min after prone positioning and confirmation of hemodynamic and ventilatory stability. Sevoflurane will be administered using automated controlled anesthesia to target approximately 1 minimum alveolar concentration. The assigned flow will be maintained unless predefined rescue criteria require an increase in fresh gas flow.
Treatment groups
Trial outcomes
Primary outcomes
Percentage Change in Dynamic Respiratory System Compliance
Dynamic respiratory system compliance (Cdyn), expressed in mL/cmH2O, will be recorded directly from the anesthesia workstation. The percentage change will be calculated as \[(Cdyn at T5 - Cdyn at T2) / Cdyn at T2\] × 100. T2 is 10 minutes and T5 is 120 minutes after reaching the assigned fresh gas flow rate in the prone position. Negative values indicate a decrease in compliance; higher values indicate better preservation of compliance.
Secondary outcomes
Change in Static Respiratory System Compliance
Static respiratory system compliance (Cstat) will be calculated as expired tidal volume divided by plateau pressure minus positive end-expiratory pressure and expressed in mL/cmH2O. Plateau pressure will be measured during a 2-second inspiratory hold. The change will be calculated as Cstat at T5 minus Cstat at T2. Negative values indicate a decrease in compliance.
Change in Driving Pressure
Driving pressure will be calculated as plateau pressure minus positive end-expiratory pressure and expressed in cmH2O. Plateau pressure will be measured during a 2-second inspiratory hold. The change will be calculated as driving pressure at T5 minus driving pressure at T2. Positive values indicate an increase in driving pressure.
Change in Airway Resistance
Airway resistance will be recorded directly from the anesthesia workstation and expressed in cmH2O·s/L. The change will be calculated as airway resistance at T5 minus airway resistance at T2. Positive values indicate an increase in airway resistance.
Change in Mechanical Power
Mechanical power during volume-controlled ventilation will be calculated as: 0.098 × tidal volume (L) × respiratory rate (breaths/min) × \[peak inspiratory pressure - 0.5 × (plateau pressure - positive end-expiratory pressure)\]. Pressures will be expressed in cmH2O and mechanical power in J/min. The change will be calculated as mechanical power at T5 minus mechanical power at T2. Positive values indicate an increase in mechanical power.