Efficacy and Safety of Sirolimus-Coated Spiral Balloon for Coronary Bifurcation Lesions

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-85
SponsorDongguan TT Medical

About this trial

This is a multicenter, prospective randomized controlled study to evaluate the safety and effectiveness of Sirolimus-coated spiral balloon (SuperFlow®) versus Paclitaxel-coated balloon (Bingo™) in the treatment of coronary bifurcation lesions.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients aged between 18 and 85 years, regardless of gender.

Patients must voluntarily participate in the study and sign an informed consent form.

Patients must demonstrate sufficient adherence to the study protocol and agree to follow-up visits at 1 month (±7 days), 6 months (±14 days), 9 months (±30 days), 12 months (±30 days), and 24 months (±30 days) post-procedure, with angiography required at 9 months (±30 days).

Patients must have evidence of myocardial ischemia.

Disqualifiers

Patients with bleeding disorders or active gastrointestinal ulcers, those who have had a stroke within the past 6 months, or those who are expected to be intolerant to dual antiplatelet therapy post-intervention.

Patients with severe renal insufficiency (creatinine level > 3.0 mg/dL or 265.2 µmol/L) and/or end-stage renal disease requiring dialysis.

Patients in cardiogenic shock.

Patients who have experienced a myocardial infarction within the week prior to enrollment.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Sirolimus coated balloon angioplasty

    Combination product

    This study involves the use of a Sirolimus-Coated Balloon (SCB) for the treatment of coronary artery disease, specifically targeting coronary bifurcation lesions. The SCB is coated with sirolimus, an antiproliferative drug that helps to prevent restenosis by inhibiting smooth muscle cell proliferation. The balloon is inflated at the target lesion site, delivering the drug directly to the arterial wall. This intervention aims to achieve vessel dilation while reducing the risk of restenosis, providing a potential alternative to stent placement.

  • Paclitaxel coated balloon angioplasty

    Combination product

    This study involves the use of a Paclitaxel-Coated Balloon (PCB) for the treatment of coronary artery disease, specifically targeting coronary bifurcation lesions. The PCB is coated with paclitaxel, an antiproliferative drug that helps to prevent restenosis by inhibiting smooth muscle cell proliferation. The balloon is inflated at the target lesion site, delivering the drug directly to the arterial wall. This intervention aims to achieve vessel dilation while reducing the risk of restenosis, providing a potential alternative to stent placement.

Treatment groups

280 Participants
are divided into 2 treatment groups
Group A: Sirolimus-coated spiral balloon (SuperFlow®)Experimental treatment 1 intervention
Group B: Paclitaxel-coated balloon (Bingo™)Active comparator 1 intervention

Trial outcomes

Primary outcomes

1

Diameter stenosis (%)

Percentage of target vessel stenosis per angiographic measurement at 6 months follow up

Time frame
6 months (±30 days)

Secondary outcomes

1

Interventional success rate

Including device success, lesion success, and clinical success Device Success: Includes successful delivery of the device and successful treatment. Successful Delivery: Successful delivery of the designated device to the lesion and release, with the delivery system retracting smoothly. Successful Treatment: Immediately post-procedure, residual stenosis of the target lesion is less than 50% with TIMI grade 3 flow (visual assessment). Lesion Success: After any interventional treatment, residual stenosis of the target lesion is less than 50% with TIMI grade 3 flow (visual assessment). Clinical Success: Based on lesion success, no major adverse cardiac events occurred during hospitalization (up to 7 days post-procedure).

Time frame
Immediate post procedure (device and lesion success), and up to 7 days post-procedure (clinical success)
2

Quantitative Flow Ratio (QFR)

In the presence of stenotic lesions in the coronary artery, the ratio of the maximum blood flow that the artery can deliver to the myocardial region to the maximum blood flow that could theoretically be obtained in that region under normal conditions.

Time frame
9 months (±30 days)
3

Rate of restenosis

Coronary angiography results showing a diameter stenosis of ≥50% are considered indicative of restenosis.

Time frame
9 months (±30 days)
4

Late lumen loss (LLL)

The difference between the minimum lumen diameter of the target lesion segment immediately post-procedure and the minimum lumen diameter of the same segment during the angiographic follow-up at 9 months post-procedure.

Time frame
9 months (±30 days)

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Dongguan TT Medical

Lead sponsor

Peking University First Hospital

Collaborator