Efficacy and Safety of Synchronized Cardiac Support in Cardiogenic Shock Patients

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-85
SponsorXenios AG

About this trial

The study aims to investigate the safety and efficacy of the Synchronized Cardiac Support treatment wit the icor kit and the Xenios console with modified sensor box ECG and Software Version 3.2.4

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Informed consent signed and dated by study patient/legal representative and investigator/authorised physician

Minimum age of 18 years

Patients in cardiogenic shock

Systolic blood pressure < 90 mmHg for at least 30 min

Disqualifiers

In case of female patients: pregnancy or lactation period

Participation in an interventional clinical study during the preceding 30 days

Previous participation in the same study

Age > 85 years

Trial design

Design model

Single group

Treatments tested in this trial

  • Synchronized Cardiac Support with the icor kit

    Device

    Patients with cardiogenic shock, requiring a venoarterial extracorporeal membrane oxygenation (VA ECMO) for cardiocirculatory stabilization will be treated with Synchronized Cardiac Support (SCS).

Treatment groups

21 Participants
are divided into 1 treatment group
Group A: venoarterial extracorporeal membrane oxygenation (VA ECMO) for cardiocirculatory stabilizationOther 1 intervention

Trial outcomes

Primary outcomes

1

Cardiocirculatory stabilization and end-organ perfusion

measured by the Change in Lactate Level

Time frame
up to 14 days

Secondary outcomes

1

Cardiocirculatory stabilization and end-organ perfusion

measured by the following parameter: Mean Arterial Pressure, Catecholamine Support, Cardiac Index, Cardiac Output and Cardiac Afterload

Time frame
up to 14 days
2

Maintain gas exchange

measured by the following parameter: Blood Gas Analysis and Mechanical Ventilation

Time frame
up to 14 days
3

Extracorporeal Life Support (ECLS) Performance

measured by the following parameter: Blood Flow, Blood Pressure, Synchronization of the patient's heartbeat, Intra-hospital transportation

Time frame
up to 14 days
4

Maintain renal function

measured by the following parameter: Fluid Balance, Renal Replacement Therapy, Creatinine and eGRF

Time frame
up to 14 days

Other outcomes

1

Safety Variables

1. Severe adverse events, i.e. Hemolysis Bleeding 2. Severe adverse device events