Evaluating How a Tinnitus Implant Affects Tinnitus Loudness in Adults With Chronic Tinnitus and Varying Levels of Hearing Loss

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorCochlear

About this trial

This study will test an experimental Tinnitus Implant System that consists of a cochlear implant, sound processor and programming software. The Tinnitus implant is surgically placed under the skin just behind the ear in the mastoid bone. It has an electrode that extends from the implant into the promontory bone of the cochlea which emits electrical signals that stimulate the auditory nerve. The sound processor is worn behind the ear and powers the implant via the coil. The study will be conducted in adults with moderate to severe chronic tinnitus who have normal hearing to moderately severe hearing loss in the inner ear. The study participants will undergo a series of tests that include evaluations of tinnitus loudness and annoyance, and self-reported questionnaires on their tinnitus and general health.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

18 years or older.

Normal hearing to moderately severe sensorineural hearing loss defined as a pure tone average (PTA) at 500, 1000, 2000 and 4000 Hz less than 65 dB HL in both ears (separately) and best-aided phoneme recognition score more than or equal to 80% in both ears (separately).

Unilateral or asymmetric subjective (no pulsatile) tinnitus. In case of asymmetric tinnitus, the worst ear must be implanted.

Tinnitus duration of at least 6 months.

Disqualifiers

Pulsatile tinnitus.

Any anatomical or structural abnormalities of the inner ear, cochlear nerve, or brainstem that would negatively impact response to study intervention (determined in a temporal bone CT and if necessary (e.g. possibility of vestibular/acoustic schwannoma) by a MRI scan of the head (of sufficient quality at the discretion of the investigator) not more than five years old at the time of enrolment

Medical contraindications limiting correct placement, activation, or treatment (determined by medical history; contraindications include brain or major ear surgery, brain or temporal bone tumor(s), recurrent ear infections within the last year, otosclerosis, prior major head trauma that results in sudden injury that causes damage to the brain and results in lasting cognitive impairment).

Any medical condition, including mental illness or substance abuse, deemed by the Investigator to likely interfere with a patient's ability to sign informed consent, cooperate and/or participate in the study, or interfere with the interpretation of the results (incl. pregnant or breastfeeding women or patients with unrealistic expectations).

Trial design

Design model

Single group

Treatments tested in this trial

  • Tinnitus Implant System

    Device

    Implanted with Tinnitus Implant System: Active Implantable Medical Device

Treatment groups

16 Participants
are divided into 1 treatment group
Group A: Tinnitus Implant SystemExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Mean change in tinnitus loudness from baseline to 6 months post-activation of the Tinnitus Implant System

Self-reported tinnitus loudness as measured on the Visual Analogue Scale-Loudness (VAS-L) where 0 is equivalent to absence of tinnitus and 100 indicates tinnitus of the greatest loudness severity

Time frame
Pre-operative baseline to 6 months post Tinnitus Implant System activation

Secondary outcomes

1

Reported device or procedure related adverse events and harms

Number of device and procedure-related adverse events and reported harms

Time frame
Pre-operative baseline to 6 months post Tinnitus Implant System activation
2

Mean change in tinnitus annoyance from baseline to 6 months post activation of the Tinnitus Implant System

Self-reported tinnitus loudness as measured on the Visual Analogue Scale-Annoyance (VAS-A) where 0 is equivalent to absence of tinnitus and 100 indicates tinnitus of the greatest annoyance severity

Time frame
Pre-operative baseline to 6 months post Tinnitus Implant System activation
3

Mean change in tinnitus perception from baseline to 6 months post activation of the Tinnitus Implant System

Self-reporting on the Tinnitus Functional Index (TFI) questionnaire

Time frame
Pre-operative baseline to 6 months post Tinnitus Implant System activation
4

Change in self-reported matches of tinnitus pitch and loudness to acoustic stimuli

Patient reported matching of tinnitus pitch (Hz) and loudness (dB SPL) with acoustic stimuli

Time frame
Pre-operative baseline, activation (Implant activation is approximately 10 weeks after surgical implantation of Tinnitus implant), 3 months post activation, 6 months post activation

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.