Evaluation of AI-Mouse Use in Patients With Hand and Wrist Conditions

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-65
SponsorNazarbayev University

About this trial

People with hand and wrist conditions, such as carpal tunnel syndrome or hand injuries, often experience pain and discomfort when using a computer mouse. This study will evaluate a new artificial intelligence (AI)-assisted computer input system ("AI-mouse") designed to reduce the amount of hand movement needed during computer tasks. Participants will complete short computer-based tasks using both a conventional mouse and the AI-assisted system while researchers measure task performance, muscle activity using surface electromyography (EMG), and participants' ratings of pain, physical strain, and usability. The study aims to determine whether the AI-assisted system can reduce physical effort and muscle load while maintaining effective computer interaction. Findings may help improve accessible computer technologies and support the development of ergonomic tools for people with hand and wrist impairments.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Adults aged 18-65 years

Diagnosis of a hand or wrist condition, including carpal tunnel syndrome or hand/wrist injury.

Receiving care at the Hand Surgery Department of the National Scientific Center of Traumatology and Orthopedics.

Medically stable and assessed by a study physician as able to safely perform light computer-based hand movements.

Disqualifiers

Severe pain or acute symptoms that may be aggravated by computer task performance.

Postoperative restrictions limiting hand or wrist movement.

Severe motor impairment preventing completion of the study tasks.

Cognitive or neurological disorders that interfere with understanding study procedures or task performance.

Trial design

Design model

Crossover

Treatments tested in this trial

  • AI-Assisted Computer Input System

    Device

    A non-invasive computer input system that uses artificial intelligence to predict the user's intended on-screen action. Instead of relying primarily on continuous cursor movement and mouse clicking, the system presents predicted actions that participants can preview, accept, or discard using minimal keyboard input. The intervention is designed to reduce repetitive hand movements during computer interaction while preserving user control. Participants complete standardized computer tasks using the system during a single study session lasting less than four minutes.

  • Conventional Computer Mouse

    Device

    A standard computer mouse used for conventional point-and-click interaction. Participants complete the same standardized computer tasks as in the experimental condition, allowing direct comparison of task performance, upper-limb muscle activity measured by surface electromyography (EMG), and participant-reported pain, physical strain, and usability.

Treatment groups

15 Participants
are divided into 2 treatment groups
Group A: Conventional MouseActive comparator 1 intervention
Group B: AI-Mouse (Preview-Accept-Discard [PAD] System)Experimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

APDF90 surface electromyography (sEMG) amplitude

90th percentile amplitude probability distribution function (APDF90) of the processed sEMG envelope recorded from selected upper-limb muscles during standardized computer tasks.

Time frame
Baseline (during each intervention condition on Day 1)
2

Muscular rest time

Percentage of task duration during which the processed sEMG envelope remained below the predefined muscular-rest threshold of 2 µV.

Time frame
Baseline (during each intervention condition on Day 1)

Secondary outcomes

1

Integrated squared dynamic acceleration

Cumulative dynamic movement workload measured by tri-axial accelerometry and expressed as integrated squared dynamic acceleration (mG²·s).

Time frame
Baseline (during each intervention condition on Day 1)
2

90th percentile dynamic acceleration

Peak dynamic movement intensity measured by tri-axial accelerometry and expressed as the 90th percentile of dynamic acceleration (mG).

Time frame
Baseline (during each intervention condition on Day 1)
3

Task completion time

Time required to complete the standardized computer task using the conventional mouse and the AI-assisted computer input system.

Time frame
Baseline (during each intervention condition on Day 1)
4

Error rate

Percentage of incorrect target selections during the standardized computer task

Time frame
Baseline (during each intervention condition on Day 1)

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: