Evaluation of Image Quality and Safety of the MyVeo Surgical Visualization Headset During Standard Neurosurgical and Reconstructive Procedures Using Compatible Microscopes.

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorLeica Microsystems (Schweiz) AG

About this trial

This study looks at how well the MyVeo surgical visualization headset works during routine surgeries. MyVeo is a wearable device that helps surgeons see the surgical area in high detail, including blood flow and tissue fluorescence, without needing to look through a traditional microscope. The study will involve patients undergoing brain, spine, ENT, or reconstructive surgery, where MyVeo is used as part of the standard care. Surgeons will rate the image quality, comfort, and safety of using MyVeo. The goal is to confirm that MyVeo provides clear images and supports safe and effective surgery. No extra procedures or risks are added for patients.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Participants must be 18 years of age or older at the time of signing the informed consent.

The participant or their legal representative must understand the study and have voluntarily signed and dated the Informed Consent Form, which has been approved by the Sponsor and the Ethics Committee for this study.

Diagnosed with condition requiring surgical intervention per user manual.

Participants must have a suspected high-grade glioma (WHO grade III-IV) as evidenced by preoperative imaging modalities, which requires surgical intervention.

Disqualifiers

Any uncontrolled systemic condition that may adversely affect the surgical outcome.

Individuals holding United States citizenship.

Known allergy to 5-ALA hydrochloride or protoporphyrin's.

Patients with porphyria (a condition characterized by the inability to break down protoporphyrin).

Trial population

The intended target population are patients undergoing a surgical procedure as defined within the intended purpose/indication for use of the respective compatible imaging system.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • MyVeo is an all-in-one surgical visualization headset used with compatible surgical microscopes and other medical imaging systems in the area of neurosurgery, ENT, spine, plastic and reconstructive su

    Device

    MyVeo is an all-in-one surgical visualization headset used with compatible surgical microscopes (ARveo 8/ARveo 8x) and other medical imaging systems. It is a digital accessory to an operating surgical microscope that enables the visualization of the surgical field through a visualization headset including: * Display of surgical field illuminated and magnified by the surgical microscope (White Light). * Display of fluorescence of fluorophores within the indicated excitation and emission ranges, as defined by the respective filters (accessories to the compatible surgical microscopes ARveo 8x such as GLOW400 and GLOW800).

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

White Light and Fluorescence image quality

Image quality will be assessed during surgery using a structured questionnaire completed by the operating surgeon. The evaluation includes white light and fluorescence imaging (GLOW400 and GLOW800) in both main surgeon (3D) and assistant (2D) modes. The following parameters will be rated: Contrast Color fidelity Stereoscopic/3D impression (main surgeon mode only) Resolution Latency (main surgeon mode only) Measurement Tool: MyVeo PMCF Study Data Collection Form - Questionnaire A and B Scale Range: 5-point Likert scale: 1. = Not available 2. = Insufficient 3. = Sufficient 4. = Very good 5. = Excellent Interpretation of Scores: Scores of 3 or higher are considered acceptable. Ratings below 3 indicate performance concerns. The outcome will be analyzed using binary coding (Pass = 3-5; Fail = 1-2).

Time frame
Periprocedural

Secondary outcomes

1

The secondary objective will be assessed by evaluating the continued safety of the device by monitoring and analyzing adverse events, device-related complications.

Safety and User Experience will be evaluated using Questionnaire, completed postoperatively by the surgical team. It captures: Dizziness due to 3D visualization Surgical delays or interruptions Injuries to patient or user Breach of sterility Tissue burns Responses are binary for Safety: 1. = Yes (event occurred) 2. = No (event did not occur) Lower scores (2 = No) indicate better safety outcomes. The outcome is acceptable if no safety events are reported. User Experience It captures: 1. ergonomics and comfort 2. adjustability 3. workflow 4. confidence in terms of decision -making Each item is rated on a 5-point Likert scale: 1. = Not available 2. = Insufficient 3. = Sufficient 4. = Very good 5. = Excellent Higher scores indicate better performance. The outcome is considered acceptable if all ratings are ≥3 (Sufficient or bett