About this trial
This single-center, non-controlled, single-arm clinical study is designed to evaluate the performance and safety of the Class III investigational device MD60002 (composed of highly purified polynucleotides at 3%) for aesthetic use in the treatment of skin imperfections and wrinkles caused by physiological facial aging.
A total of 43 adult subjects presenting with facial wrinkles (Lemperle Wrinkle Severity Scale score ≥ 1) will be enrolled. Participants will receive intradermal injections of MD60002 according to a standardized protocol.
The primary endpoint is the evaluation of aesthetic improvement measured by the change in the Lemperle Wrinkle Severity Scale (LWSS) score from baseline to the 30-day follow-up visit. Secondary endpoints include patient-reported subjective satisfaction evaluated via the Global Aesthetic Improvement Scale (GAIS), alongside comprehensive safety, tolerability, and device deficiency monitoring in accordance with ISO 14155 guidelines.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
None
Disqualifiers
None
Trial design
Single group
Treatments tested in this trial
Device: MD60002
DeviceMD60002 is a sterile, biodegradable, isotonic intradermal gel formulated with 3% highly purified polynucleotides of fish origin in a physiological buffer. The device is supplied in a pre-filled 2 ml syringe, packaged in a blister along with sterile 30G 1/2" needles. Participants will receive slow intradermal injections of MD60002 into targeted facial areas (up to a maximum volume of 2 ml per session depending on the defect) using strict aseptic techniques and following the sponsor's provided training.
Treatment groups
Trial outcomes
Primary outcomes
Change from Baseline in Lemperle Wrinkle Assessment Scale (LWSS) Score
Change in wrinkle severity evaluated using the Lemperle Wrinkle Assessment Scale (LWSS). The scale ranges from 0 (no wrinkles) to 5 (very deep wrinkles, redundant fold). A lower score indicates greater aesthetic improvement.
Incidence and Severity of Treatment-Emergent Adverse Events (TEAEs) and Device Defect Logs
Assessment of device safety evaluated through the recording, incidence, severity, and causal relationship of local and systemic adverse events, local injection site reactions (e.g., erythema, edema, pain), and device defects throughout the study duration.
Investigator Global Aesthetic Improvement Scale (GAIS) Rating
Assessment of overall aesthetic improvement rated by the Investigator using the GAIS 5-point scale (1 = Very Much Improved, 2 = Much Improved, 3 = Improved, 4 = No Change, 5 = Worse).
Secondary outcomes
Subject Satisfaction Score Measured by Global Aesthetic Improvement Scale (GAIS)
Subject-assessed aesthetic improvement using the Global Aesthetic Improvement Scale (GAIS), a 5-point ordinal scale (1 = Very Much Improved, 2 = Much Improved, 3 = Improved, 4 = No Change, 5 = Worse). Success is defined as at least 70% of subjects reporting a score of 3 or lower.
Incidence and Severity of Adverse Events (AEs) and Device Deficiencies
Incidence, frequency, and severity of treatment-emergent adverse events (AEs), serious adverse events (SAEs), device-related adverse effects (ADEs/SADEs), and device deficiencies recorded throughout the study.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: