The main objective of this study is to evaluate whether digital fetal scalp stimulation improves fetal well-being in fetuses with suspicious or pathological cardiotocographic recordings, showing an improvement in cardiotocographic recording patterns and normal values in intrapartum fetal scalp blood results.
Upon detection of a suspicious or pathologic cardiotocographic recording, the investigators need to perform an objective verification of fetal well-being.
Currently, fetal scalp blood is the reference test to assess intrapartum fetal hypoxia, according to the protocols of the Spanish Society of Gynecology and Obstetrics.
This procedure lasts about 5 minutes and consists of taking a small sample of the fetal scalp, through a vaginal exploration, the blood is collected in a thin tube and analyzed by a machine in the delivery room obtaining the results in a few minutes.
The investigators emphasize that this test is not part of the study, as long as the monitor is suspicious or pathological, it will be performed according to protocol to objectively assess fetal well-being.
Currently there are studies that support the use of fetal scalp stimulation as an alternative technique to assess intrapartum fetal well-being and predict neonatal outcomes, but they also highlight its limited evidence.
Digital fetal scalp stimulation is a NON-invasive method, as no instrument is required and fetal stimulation is a 30-60 second surface rubbing pressure, which is performed manually, through vaginal exploration, the same technique the investigators use to assess dilation during the labor process.
Each patient will be randomly assigned to a study group:
Experimental group: before the extraction of capillary blood from the fetal scalp, fetal head stimulation will be performed, a technique that poses no risk to the baby. The researchers need the consent of the participants to perform this technique and collect data.
Control group: fetal head stimulation will not be applied, but data from the clinical history necessary for this study will be collected.
In no case will extraordinary or unnecessary tests be performed for participation in this study.
This study will have an Informed Consent document.
This study will be carried out at the Fundación Jiménez Díaz and Zarzuela and will include 182 patients for 24 months.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
None
Disqualifiers
None
Trial design
Parallel
Treatments tested in this trial
Digital fetal scalp stimulation dFSS
Diagnostic testDigital fetal scalp stimulation will be performed for a period of 30 seconds, prior to obtaining the fetal blood sample. Digital fetal scalp stimulation will be performed by vaginal touch with a gauze pad and rubbing the fetal scalp with pressure for 30 to 60 seconds.
Treatment groups
Trial outcomes
Primary outcomes
Percentage of fetuses with positive response to digital fetal scalp stimulation, intrapartum ph greater than 7.20, newborn ph greater than 7.20 and good neonatal outcomes
To evaluate the percentage of fetuses with suspicious or pathologic cardiotocographic recording patterns compatible with risk of loss of fetal well-being that respond positively to digital fetal scalp stimulation, obtain an intrapartum pH greater than 7.20, at birth a pH greater than 7.20, and good neonatal outcomes.
Secondary outcomes
Differences in the cardiotocographic pattern of fetuses with digital fetal scalp stimulation vs. fetuses without digital fetal scalp stimulation
Significant differences in the cardiotocographic pattern of fetuses with digital fetal scalp stimulation vs. fetuses without digital fetal scalp stimulation The FHR pattern in the cardiotocographic recording is closely monitored for 1 to 10 minutes, using a 5-minute mean. Assess an acceleration of FHR defined as an increase in FHR ≥ 15 bpm (beats per minute for at least 15 seconds or normal FHR variability (5 to 25 bpm), or both. The presence of FHR acceleration or increased variability when previously reduced, or both, is interpreted as a positive response.
Differences in the results of intrapartum fetal scalp blood of fetuses with digital fetal scalp stimulations versus fetuses without digital fetal scalp stimulation
Significant differences in intrapartum pH results in fetuses with digital fetal scalp stimulations versus fetuses without digital fetal scalp stimulation
Differences in newborn ph results of fetuses with digital fetal scalp stimulations versus fetuses without digital fetal scalp stimulation
Significant differences in newborn pH outcomes in fetuses with digital fetal scalp stimulations versus fetuses without digital fetal scalp stimulation
Differences in the first minute apgar scores of the newborns in fetuses with digital fetal scalp stimulations versus fetuses without digital fetal scalp stimulation
Significant differences in the minute-of-life Apgar scores of newborns in fetuses with digital fetal scalp stimulations versus fetuses without digital fetal scalp stimulation
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Instituto de Investigación Sanitaria de la Fundación Jiménez Díaz
Lead sponsor
CEU San Pablo University
Collaborator
Hospital Universitario Sanitas La Zarzuela
Collaborator