Examining and Comparing the Temporal Changes and Results of Cosmetic, Quality of Life and Patient Satisfaction Achieved With Immediate and Delayed-immediate Implant-based Breast Reconstruction Procedures and Contralateral Symmetrization Techniques

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexFemale
Age18-65
SponsorNational Institute of Oncology, Hungary

About this trial

This is a response-adaptive (RAR) prospective randomized study with a long-term follow-up and the aim of this clinical study is to measure with qualitative and quantitative indicators the changes in cosmetic results, quality of life and patient satisfaction after breast reconstructive surgery with silicone implant (following SSM, ASM or NSM mastectomy) and symmetrization (mastopexy and/or silicone implant and/or Ultrapro mesh sling technique) over time.

According to the hypothesis of the study, the results of implant-based breast reconstruction and symmetrization following advanced postmastectomy techniques significantly decrease over time and later results limited patient satisfaction rate.

This is mainly due to the fact that over time, the natural breast differs from the reconstructed breast with silicone implant. Because of the different biological properties (gravity results ptosis on breast with mastopexy, significant volume increasement of the breast with mastopexy due to endocrine therapy, gradually progressive capsular contracture on the tumorous side, nipple flattening, nipple tattoo fading etc.) the two sides change differently resulting in significant asymmetry and consequently could lead to decreased patient satisfaction.

The high degree of asymmetry over time (which can be similar to the difference between the result of a simple mastectomy and natural breast (control group)), may indicates additional surgeries or usage of medical devices, putting a financial burden on the patient and the health system. On the other hand, the symmetry can be achieved with bilateral skin-sparing mastectomies and implant-based immediate or delayed-immediate reconstructions is clearly better and change less with time. The mastectomy of the contralateral disease-free side is considered as an unreasonable burden for moderate risk patients.

The information such as the need for multiple surgeries, change in symmetry over time etc., should be an important part of the professional decision-making mechanism and the surgeon should inform the patient during the primer surgery. Nowadays due to the lack of evidence-based knowledge, it is not part of the patient's information and surgical planning internationally. Planning breast units, attention, capacity and financial resources must also be provided to meet the long-term needs of patients who underwent postmastectomy breast reconstruction. Simple mastectomy with an external prosthesis can be an alternative for patients with intolerable degree of asymmetry or on the contrary, the results may justify the need for bilateral mastectomy and reconstruction even in the absence of high oncological risk and for purely symmetrical and cosmetic reasons.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Under the age of 65 with uni- or bilateral primary breast cancer ( clinical Stage 0-III), needing modern skin sparing mastectomy, nipple sparing mastectomy or areola sparing mastectomy independently of the axillary surgery, having immediate or delayed-immediate implant based reconstrucion on the ipsilateral side and symmetrisation on the contralateral side ( mastopexy and/or implant based reconstruction and/or breast sling with ultrapro mesh)

Control group: patients under 65 years with unilateral simplex mastectomy without breast reconstruction

Disqualifiers

In case the patient does not volunteer for the examination or the follow-ups

Age above 65 years or poor general health condition, where the estimated life expectancies would be less than 2 years even without the tumorous disease

Malignant invasive tumor in the past history (except for non-melanoma skin tumors)

Mastectomyand reconstruction performed due pregnancy associated breast cancer

Trial population

The aim of the study is to evaluate the time related cosmetic results in the subgroups of implant based postmastectomy reconstruction: mastopexy, mastopexy with Ultrapro sling technique, mastopexy with silicone implant and mastopexy with silicone implant and Ultrapro sling technique. The planned subgroups contain of 80-80 cases and the control group contains also 80 cases. Planned number of the patients (calculated patients number plus 10%): 80x6=480+ 48 cases ∑528 cases should be included.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • A: expander-silicone implant exchange and contralateral symmetrization with mastopexy and if needed with volume reduction

    Procedure/Surgery

    expander-silicone implant exchange and contralateral symmetrization with mastopexy and if needed with volume reduction

  • B: expander-silicone implant exchange with contralateral symmetrization with mastopexy and Ultrapro sling

    Procedure/Surgery

    expander-silicone implant exchange with contralateral symmetrization with mastopexy and Ultrapro sling

  • C: expander-silicone implant exchange and contralateral symmetrization with mastopexy and silicone implant augmentation

    Procedure/Surgery

    expander-silicone implant exchange and contralateral symmetrization with mastopexy and silicone implant augmentation

  • D: expander-silicone implant exchange and contralateral symmetrization with mastopexy and Utrapro sling and silicone implant augmentation

    Procedure/Surgery

    expander-silicone implant exchange and contralateral symmetrization with mastopexy and Utrapro sling and silicone implant augmentation

  • E: unilateral simple mastectomy

    Procedure/Surgery

    unilateral simple mastectomy

  • F: after bilateral SSM, ASM, NSM, expander-implant exchange

    Procedure/Surgery

    after bilateral SSM, ASM, NSM, expander-implant exchange

Treatment groups

528 Participants
are divided into 6 treatment groups

6

Treatment groups

See each treatment group below.

Group A: A:Exp-impl-mastopexy1 intervention
Group B: B: exp-impl-mastopexy+mesh1 intervention
Group C: C: exp-impl-mastopexy+implant1 intervention
Group D: D: exp-impl-mastopexy+implant+mesh1 intervention
Group E: E: simple masectomy1 intervention
Group F: F: bilateral exp-impl1 intervention

Trial outcomes

Primary outcomes

1

Quality of life: BREAST-Q validated questionnaire

Correlation analysis of quality of life achieved by various surgical techniques. The quality of life is measured by BREAST-Q validated questionnaire. According to this, we give a score in a 1-100 scale measuring the variables of "psychosexual wellbeing" and "physical wellbeing". We use preoperatively a preoperative questionnaire and postoperatively a postoperative questionnaire. Higher rates show better quality of life. The questionnaires are filled before the procedure and after the surgery 4th-6th weeks then postoperatively in the 3rd months and every 6th months

Time frame
up to 5 years
2

Patient satisfaction: BREAST-Q validated questionnaire

Correlation analysis of patients' satisfaction achieved by various surgical techniques. The patients' satisfaction life is measured by BREAST-Q validated questionnaire. According to this, we give a score in a 1-100 scale measuring the variables of "satisfaction with the breast", "discomfort by radiotherapy" We use preoperatively a preoperative questionnaire and postoperatively a postoperative questionnaire. Higher rates show better patients' satisfaction. The questionnaires are filled before the procedure and after the surgery 4th-6th weeks then postoperatively in the 3rd months and every 6th months.

Time frame
up to 5 years

Secondary outcomes

1

Objective cosmetic results

To exclude subjectivity, the aesthetic results were classified objectively based on photo documentation using the Breast Cancer Conservative Treatment-cosmetic results (BCCT.core) software (version 20). The photo documentation performed the standard way in 5 position (antero-posterior (ap), 45 degree oblique and 90 degree lateral), in ap direction both ways arms up and down with strict adherence to personal privacy policies. BCCT.core software provides an extensive set of automated measurements using digital marks to establish a 4-point classification scale (excellent, good, fair and poor) and the overall assessment of cosmetic outcomes. Objective aesthetic results classified as fair or poor by the BCCT.core software were considered unacceptable. These numerical results can be statistically analyzed. The results are collected and averaged.

Time frame
up to 5 years

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.