About this trial
This is a multicenter, prospective, observational study ,the aim of this study is to find factors affecting selection of double-chamber leadless pacemaker in patients with atrioventricular block and ambulatory atrioventricular synchronous pacing status over time using a leadless ventricular pacemaker.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients diagnosed with atrioventricular conduction block, meeting the indications for dual-chamber leadless pacemakers as per the "Chinese Expert Consensus on Clinical Application of Leadless Pacemakers (2022)".
Age ≥18 years.
Expected lifespan ≥1 year.
Consent to sign an informed consent form and cooperate in the collection of baseline data and subsequent follow-ups
Disqualifiers
Patients anticipated to have a high ventricular pacing proportion (>40%) and with left ventricular ejection fraction less than 50%.
Patients with persistent atrial fibrillation and a high expected ventricular pacing proportion.
Post-tricuspid valve mechanical valve replacement surgery.
Patients with inferior vena cava pathway anomalies, precluding passage of the leadless pacemaker's delivery sheath.
Trial population
Patients diagnosed with atrioventricular conduction block, meeting the indications for dual-chamber leadless pacemakers as per the "Chinese Expert Consensus on Clinical Application of Leadless Pacemakers (2022)".All patients should sign written informed consent for agreement of the implantation procedure.
Trial design
Other
Prospective
Treatments tested in this trial
Micra AV implantation
DevicePatients received Micra AV implantation
Treatment groups
Trial outcomes
Primary outcomes
Complete the survey questionnair before implanting a pacemaker
Complete the survey questionnair
The percentage of atrioventricular synchrony at 3 months after Micra AV implantation.
The percentage of atrioventricular synchrony will be calculated based on the recording of a 20-minute resting period in the outpatient consulting room, via dividing the total number of AV synchronous cycles by the total number of cardiac cycles recoded by a Holter. An AV synchronous cycle will be defined as a paced or sensed ventricular beat within 300 ms following a surface ECG confirmed P-wave.
Secondary outcomes
Immediate success rate of Micra AV implantation.
Successfully implant a Micra AV during procedure.
The percentage of atrioventricular synchrony at 6, 12 months after Micra AV implantation.
The percentage of atrioventricular synchrony will be calculated based on the recording of a 20-minute resting period in the outpatient consulting room, via dividing the total number of AV synchronous cycles by the total number of cardiac cycles recoded by a Holter. An AV synchronous cycle will be defined as a paced or sensed ventricular beat within 300 ms following a surface ECG confirmed P-wave.
Ventricular pacing threshold, at 3 months, 6 months, and 1 year after Micra AV implantation.
Measuring the ventricular pacing threshold by a programmer at the outpatient clinic at 3,6 and 12 month.
Ventricular sensing at 3 months, 6 months, and 1 year after Micra AV implantation.
Measuring ventricular sensing by a programmer at the outpatient clinic at 3,6 and 12 month.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Xiaohan Fan
Lead sponsor
Fu Wai Hospital, Beijing, China
Sponsor institution
Tianjin Chest Hospital
Collaborator
Beijing Friendship Hospital
Collaborator
Beijing Hospital
Collaborator
Peking University First Hospital
Collaborator