About this trial
The goal of this randomized pilot study is to determine whether adding expiratory muscle strength training (EMST) to standard pelvic floor muscle training (PFMT) is feasible and may help improve stress urinary incontinence (SUI) in females assigned at birth, ages 18 to 79. SUI is urine leakage that occurs during activities such as coughing, sneezing, laughing, or exercising.
The main questions this study aims to answer are:
Can participants complete the combined exercise program, and is it acceptable to them?
Does adding EMST to PFMT lead to greater improvements in urinary leakage symptoms and participants' perceived improvement compared with PFMT alone?
Does adding EMST improve breathing muscle strength and pelvic floor muscle activity?
Researchers will enroll 24 participants and randomly assign them to one of two groups:
Group 1: Standard physical therapy, including pelvic floor muscle training.
Group 2: The same physical therapy and pelvic floor muscle training, with the addition of expiratory muscle strength training.
Both groups will receive six weeks of supervised physical therapy, with one session each week. Participants will attend seven study visits over approximately seven weeks, including an initial assessment and six treatment visits.
Participants will:
Complete questionnaires about urinary leakage symptoms and perceived improvement.
Have their breathing muscle strength measured using a test that measures how strongly they can breathe out.
Have pelvic floor muscle activity measured using a surface electromyography (sEMG) sensor.
Perform prescribed home exercises and record their exercise completion in a log.
Participants in both groups will practice pelvic floor muscle exercises at home. Participants in the combined-treatment group will also use a device that provides resistance when breathing out. They will perform five sets of five breaths daily, with resistance based on their measured breathing muscle strength.
Researchers will assess whether participants complete the study visits, follow the home exercise program, complete the study measures, and report satisfaction with the program. They will also monitor any unwanted effects related to the exercises or assessments.
The study will explore whether adding EMST to PFMT may improve urinary leakage symptoms, breathing muscle strength, and pelvic floor muscle activity. Participants may experience improvements, but benefits are not guaranteed. The results will help researchers determine whether a larger study is needed to better evaluate this combined treatment for stress urinary incontinence.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Female assigned at birth, 18-79 years of age
Disqualifiers
Males assigned at birth
Trial design
Parallel
Treatments tested in this trial
Pelvic floor muscle training
Other interventionPFMT: Participants will be instructed in a home exercise program of pelvic floor muscle training (PFMT) at 5 sets of 5 submaximal repetitions daily. Through the 6 intervention sessions, exercise repetitions will increase to up to 100 per day in gravity dependent positions.
Expiratory muscle strength training
Other interventionEMST: Participants will use a calibrated expiratory resistance device at 50% of MEP, 5 sets of 5 breaths daily.
Treatment groups
Trial outcomes
Primary outcomes
Attrition
Attrition will be assessed as a feasibility outcome to evaluate participant retention throughout the study. Attrition will be defined as the proportion of enrolled participants who discontinue study participation before completing the final study visit (Visit 7). The attrition rate will be calculated by dividing the number of participants who withdraw or discontinue participation before study completion by the total number of participants enrolled, multiplied by 100. The number and percentage of participants who complete the study will also be reported. Reasons for withdrawal or discontinuation will be documented when available. Attrition and retention rates will be summarized descriptively using counts, percentages, and 95% confidence intervals to evaluate the feasibility of participant retention in the study.
Eligibility rates
Eligibility rate will be assessed as a feasibility outcome to evaluate the proportion of individuals screened who meet the study's eligibility criteria. The eligibility rate will be calculated by dividing the number of individuals determined to be eligible by the total number of individuals screened and multiplying by 100. Eligibility will be determined based on the study's prespecified inclusion and exclusion criteria, including an ICIQ-UI SF score of at least 6. The number and percentage of individuals who are eligible and ineligible will be summarized descriptively. Reasons for ineligibility will be documented when available. The eligibility rate will be reported as a percentage with a 95% confidence interval to evaluate the feasibility of identifying an appropriate study population.
Secondary outcomes
Global rating of change
The Global Rating of Change (GROC) is a patient-reported measure used to assess participants' perceived overall change in symptoms following the intervention. At the final study visit, participants will rate how their urinary incontinence symptoms have changed compared with their status before beginning the intervention. Responses will be recorded using a 7-point ordinal scale ranging from 1 (very much better) to 7 (very much worse), with a score of 4 indicating no change. Lower scores indicate greater perceived improvement, whereas higher scores indicate greater perceived worsening. The GROC will be administered at Visit 7 and used to characterize participants' overall perceptions of treatment-related change.
Maximum expiratory pressure
Maximal expiratory pressure (MEP) is an objective measure of respiratory muscle strength that assesses the maximum pressure generated during a forceful expiration against an occluded airway. MEP will be measured using a respiratory pressure manometer and expressed in centimeters of water (cm H₂O). Participants will be seated and instructed to inhale maximally, followed by a forceful, sustained exhalation into the manometer mouthpiece. Measurements will be repeated according to a standardized testing protocol, with adequate rest between attempts to minimize fatigue. The highest acceptable and reproducible pressure value will be recorded for analysis. Higher MEP values indicate greater expiratory pressure-generating capacity and are used to characterize respiratory muscle strength at baseline and assess changes following the intervention. MEP will be measured at Visits 1, 4, and 7.
Maximum expiratory pressure
Maximal expiratory pressure (MEP) is an objective measure of respiratory muscle strength that assesses the maximum pressure generated during a forceful expiration against an occluded airway. MEP will be measured using a respiratory pressure manometer and expressed in centimeters of water (cm H₂O). Participants will be seated and instructed to inhale maximally, followed by a forceful, sustained exhalation into the manometer mouthpiece. Measurements will be repeated according to a standardized testing protocol, with adequate rest between attempts to minimize fatigue. The highest acceptable and reproducible pressure value will be recorded for analysis. Higher MEP values indicate greater expiratory pressure-generating capacity and are used to characterize respiratory muscle strength at baseline and assess changes following the intervention. MEP will be measured at Visits 1, 4, and 7.
surface EMG
Pelvic floor muscle activity will be assessed using vaginal surface electromyography (sEMG) with an intravaginal sensor to measure the amplitude of electrical activity generated during pelvic floor muscle contractions. A trained, licensed physical therapist with pelvic health training will position the vaginal sensor according to the device manufacturer's instructions. Participants will be instructed to perform a maxiumal and submaximal voluntary pelvic floor muscle contraction, and the sEMG system will record the resulting electrical activity. Amplitude will be expressed in microvolts (µV), with higher values generally indicating greater recorded electrical activity during contraction. Measurements will be obtained using a standardized testing protocol at Visits 1, 4, and 7 to characterize pelvic floor muscle activation and explore changes following the intervention.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: