First in Human Study to Assess Safety and Efficacy of an Implantable Nitinol Device in the Treatment of Keratoconus

ConditionKeratoconus
Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorRecornea Srl

About this trial

This Study is a First In Human clinical investigation addressed to evaluate the safety and efficacy of a novel intra-corneal nitinol device (Investigational Medical Device: GROSSO® implant) for the treatment of advanced keratoconus disease of the eye.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Signed and dated informed consent form.

Male and female ≥ 18 years old.

Not recommended for ICRS.

Recommended for keratoplasty.

Disqualifiers

Inability of patient and/or relatives to understand the clinical investigation procedures and thus inability to give informed consent.

Untreated progressive KC.

Single functioning eye.

Other ocular diseases (eyelids malposition, uveitis, ocular hypertension, glaucoma, cataract, retinal disorders) or corneal surgeries (refractive corneal surgery, keratoplasty), except corneal crosslinking.

Trial design

Design model

Single group

Treatments tested in this trial

  • Nitinol net for intracorneal implant for keratoconus treatment

    Device

    The investigational corneal implant device is designed for patients with keratoconus. It is intended to be surgically implanted into the cornea as a permanent implant and is made of nitinol. The device is intended to improve corneal stability and visual outcomes.

Treatment groups

12 Participants
are divided into 1 treatment group
Group A: Study groupExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Incidence of Serious Adverse Device Effects (SADE), Adverse Events (AE), and Serious Adverse Events (SAE)

Number and type of adverse events, serious adverse events, and serious adverse device effects observed during follow-up.

Time frame
From enrolment up to 12 months post-procedure
2

Changes in corneal alterations from baseline to 12 months.

Slit Lamp corneal assessments to evaluate: * Corneal inflammation * Corneal infection * Corneal stromal lysis * Corneal melting * Corneal stromal infiltration * Corneal neo vessels * Persistent corneal epithelial defects Observations will be graded from 0 (Absence) to 3 (Severe)

Time frame
From baseline up to 12 months post-procedure
3

Changes in total and epithelial corneal thickness (central and minimum) from baseline to 12 months.

Measurement of total and epithelial corneal thickness (central and minimum)

Time frame
From baseline up to 12 months post-procedure
4

Changes in IOP from baseline to 12 months

IOP is measured with tonometer

Time frame
From baseline up to 12 months post-procedure

Secondary outcomes

1

Changes in Best Distance Spectacle Corrected Visual Acuity (BDSCVA) from baseline to 12 months

BDSCVA is performed using ETDRS (Early Treatment Diabetic Retinopathy Study) refraction and vision testing protocol.

Time frame
From baseline up to 12 months post-procedure
2

Changes in topographic keratometry values from baseline to 12 months

Corneal topography is performed by using the topographer. The values collected are Kmax, K steep, K flat and Km.

Time frame
From baseline up to 12 months post-procedure
3

Changes in topographic and refractive astigmatism from baseline to 12 months

Topographic astigmatism is measured in dioptres with the Topographer. Refractive astigmatism is measured in dioptres and axis, determined by refraction using ETDRS optotypes

Time frame
From baseline up to 12 months post-procedure
4

Changes in Manifest Refraction Spherical Equivalent (MRSE) from baseline to 12 months

MRSE is measured in dioptres, determined by refraction using ETDRS optotypes

Time frame
From baseline up to 12 months post-procedure

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.